Phantom dosimetry and cancer risks estimation undergoing 6 MV photon beam by an Elekta SL-25 linac

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
2

Year Published

2021
2021
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 41 publications
0
5
0
2
Order By: Relevance
“…Since the MCNPX outs are per incident neutron, then the neutron source strength in equations (2)-( 4) is equal to one (Q = 1). By having Φ dir from MCNPX and considering d = 100 cm in equation (2), it is quantified a coefficient equal to 0.052696. By fitting fluences of the scattered and thermal neutrons in terms of the internal surface area of rooms based on equations (3) and (4) coefficients α and β were obtained as follows: For example, the fitting of thermal fluences to get coefficient α is shown in figure 8.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Since the MCNPX outs are per incident neutron, then the neutron source strength in equations (2)-( 4) is equal to one (Q = 1). By having Φ dir from MCNPX and considering d = 100 cm in equation (2), it is quantified a coefficient equal to 0.052696. By fitting fluences of the scattered and thermal neutrons in terms of the internal surface area of rooms based on equations (3) and (4) coefficients α and β were obtained as follows: For example, the fitting of thermal fluences to get coefficient α is shown in figure 8.…”
Section: Resultsmentioning
confidence: 99%
“…In the accelerator, electron beams collide with a target (such as tungsten) and produce x-rays. The use of x-ray machines necessitates radiation protection [1,2].…”
Section: Introductionmentioning
confidence: 99%
“…Apabila dibutuhkan satuan dosis dalam Gy maka perlu mengalikan dengan faktor pengali (multiplier). Pada berkas foton 6 MV nilai faktor pengali sebesar 8,93x10 15 untuk mendapatkan dosis yang diterima per 1 Gy (dalam satuan Gy) [15]. Diagram alir dalam penelitian ini ditunjukkan pada Gambar 14.…”
Section: Menjalankan (Running) Program Mcnpxunclassified
“…Still, the healthy organs and tissues might be exposed to the unnecessary radiation dose when the radiation beam passes by or because of the scattered radiation. 1 The results of the pretreatment QA are used to predict the treatment outcome on the patient from the alterations in the dose-volume histograms for the contoured planning target volume (PTV) and organs at risk. 2 One of the reasons for this low sensitivity is that the phantom dimension used for the pre-treatment QA is totally different from the real patients.…”
Section: Introductionmentioning
confidence: 99%