2020
DOI: 10.1016/j.fluid.2020.112659
|View full text |Cite
|
Sign up to set email alerts
|

Phase equilibria and energetics of binary mixtures of water with highly hydrophilic [EMIM]-based ionic liquids: Methanesulfonate, methylsulfate, and dimethylphosphate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 36 publications
0
6
0
Order By: Relevance
“…To the best of our knowledge, no data about the [C 1 Py]­[DMP] density is presented. In the open literature, there are a few density data for pure [C 1 C 1 IM]­[DMP], , or [C 1 C 2 IM]­[DMP] and their ethanolic solution. ,,, Figure S7 in the SI shows the relative deviations between the data measured in this work and the literature results at a temperature of 298.15 K for pure imidazolium-based ILs.…”
Section: Resultsmentioning
confidence: 82%
See 3 more Smart Citations
“…To the best of our knowledge, no data about the [C 1 Py]­[DMP] density is presented. In the open literature, there are a few density data for pure [C 1 C 1 IM]­[DMP], , or [C 1 C 2 IM]­[DMP] and their ethanolic solution. ,,, Figure S7 in the SI shows the relative deviations between the data measured in this work and the literature results at a temperature of 298.15 K for pure imidazolium-based ILs.…”
Section: Resultsmentioning
confidence: 82%
“…In the open literature, there are a few viscosity data for pure [C 1 C 1 IM]­[DMP], ,,,, [C 1 C 2 IM]­[DMP], , and their binary ethanolic solution. ,,, To the best of our knowledge, there is no data literature data on the viscosity of the [C 1 Py]­[DMP] for comparison. Literature data varies widely, and the declared viscosity value for pure [C 1 C 1 IM]­[DMP] at 298.15 K ranges from (223 to 337) mPa·s.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…NRTL model has been widely proved to perform adequately for the purpose in our previous studies. [1][2][3][4][5][6]8 Bearing in mind that the selection of accurate data and rational fitting strategy are also important prerequisites for establishing a globally performing model, the procedure we adopted for the evaluation of adjustable parameters was as follows. For the (water + [BMPYR][OTF]) system, the VLE and H E data measured in this work were simultaneously correlated using the weighted least-squares method, the objective function minimalized being…”
Section: Phase Equilibria and Thermalmentioning
confidence: 75%