2021
DOI: 10.1016/j.fluid.2021.113199
|View full text |Cite
|
Sign up to set email alerts
|

Phase equilibria and volumetric and viscosity behavior of the aqueous double salt ionic liquid [EMIM][SCN] [MeSO3](1-)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…When the apparatus is operated in the continuous mode, an operator continuously monitors the water activity and temperature readings, waiting for them to stabilize. Several studies proved that AQUALAB 4TE is a reliable apparatus for measuring water activity. During the current research, AQUALAB’s worth was additionally validated.…”
Section: Methodsmentioning
confidence: 77%
See 1 more Smart Citation
“…When the apparatus is operated in the continuous mode, an operator continuously monitors the water activity and temperature readings, waiting for them to stabilize. Several studies proved that AQUALAB 4TE is a reliable apparatus for measuring water activity. During the current research, AQUALAB’s worth was additionally validated.…”
Section: Methodsmentioning
confidence: 77%
“…The main result of the study is a thermodynamic model of the H 2 O–H 2 SO 4 –UO 2 SO 4 system based on Pitzer–Simonson–Clegg (PSC) equations, , which has been developed using both literature data on water activity and solid–liquid equilibria in the H 2 O–H 2 SO 4 –UO 2 SO 4 and H 2 O–UO 2 SO 4 systems, and novel experimental data on water activity in the ternary system mentioned. Activity of water in the H 2 O–H 2 SO 4 –UO 2 SO 4 solutions has been determined at 298.15, 310.65, and 323.15 K by means of an apparatus AQUALAB 4TE, an increasingly popular dew-point hygrometer.…”
Section: Introductionmentioning
confidence: 99%
“…NRTL model has been widely proved to perform adequately for the purpose in our previous studies. [1][2][3][4][5][6]8 Bearing in mind that the selection of accurate data and rational fitting strategy are also important prerequisites for establishing a globally performing model, the procedure we adopted for the evaluation of adjustable parameters was as follows. For the (water + [BMPYR][OTF]) system, the VLE and H E data measured in this work were simultaneously correlated using the weighted least-squares method, the objective function minimalized being…”
Section: Phase Equilibria and Thermalmentioning
confidence: 99%