2005
DOI: 10.1039/b503727a
|View full text |Cite
|
Sign up to set email alerts
|

Photo-induced chemical vapor generation with formic acid for ultrasensitive atomic fluorescence spectrometric determination of mercury: potential application to mercury speciation in water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
136
3

Year Published

2006
2006
2016
2016

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 193 publications
(141 citation statements)
references
References 35 publications
2
136
3
Order By: Relevance
“…This procedure was based on a post-column mix and reaction with formic acid. Under UV irradiation, the decomposition of organic mercury species and reduction of Hg 2+ could be completed in one step [25] with this proposed photo-induced CVG system without nano-TiO 2 catalyst.…”
Section: Introductionmentioning
confidence: 92%
“…This procedure was based on a post-column mix and reaction with formic acid. Under UV irradiation, the decomposition of organic mercury species and reduction of Hg 2+ could be completed in one step [25] with this proposed photo-induced CVG system without nano-TiO 2 catalyst.…”
Section: Introductionmentioning
confidence: 92%
“…This instrument as described in details in previous works 37,38 was equipped with coded high intensity hollow cathode lamps (HCL) of As, Sb, and Bi, a quartz argon−hydrogen flame atomizer and a hydride generator consisting of a four-channel peristaltic pump and a quartz gas liquid separator (GLS). An Agilent 7700x inductively coupled plasma mass spectrometer (ICP-MS) (Aglient Technologies, U.S.A.) was also used to evaluate the proposed method.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…Quantification of As, Sb, and Bi was accomplished by flow injection HG-AFS, which is similar to our previous works. 37,38 Briefly, 2 mL of tested solution was initially directed to the sample loop through a six-port valve by a peristaltic pump. The valve was activated to pass the carrier solution (3% (v/v) HCl solution) to flush the digested solution to mix with 2% (m/v) KBH 4 solution containing 0.5% (m/v) KOH for the generation of As, Sb, and Bi hydrides.…”
Section: ■ Materials and Methodsmentioning
confidence: 99%
“…In addition to UV [92] and ultrasonic [93] irradiation, solution cathode glow discharge (SCGD) can also promote the CVG of Hg species within formic acid [94]. A novel SCGD induced CVG was developed as interface to on-line couple LC with AFS for the speciation of Hg 2+ , MeHg and EtHg [95].…”
Section: Rp-hplc-icp-ms Rp-hplc-esi-msmentioning
confidence: 99%