Pitfalls and Artefacts using Contrast Enhanced Ultrasound

Abstract: Ultrasound is the method of choice in the detection and characterization of diffuse and focal organic diseases. For B-mode and colour (power) Doppler ultrasound, besides manual skills, (hands-on) a technical knowledge about ultrasound images is of the upmost importance for the investigator. Contrast enhanced ultrasound (CEUS) has become an important diagnostic tool for hepatic, renal, pancreatic indications and several others due to: (a) an increasing rate of studies resulting in sufficient evidence especially… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
70
0
13

Year Published

2012
2012
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 100 publications
(83 citation statements)
references
References 20 publications
0
70
0
13
Order By: Relevance
“…grey scale ultrasound or color flow Doppler techniques do not have the sensitivity to identify many of the vascular differences in FLLs. This technique fails to reliably differentiate between malignant and benign lesions [13,[25][26][27][28][29][30]. Some FLLs are particularly difficult to diagnose even by biopsy because of their small size (<10 mm) or superficial location (close to liver capsule) [12,15,26].…”
Section: Discussionmentioning
confidence: 99%
“…grey scale ultrasound or color flow Doppler techniques do not have the sensitivity to identify many of the vascular differences in FLLs. This technique fails to reliably differentiate between malignant and benign lesions [13,[25][26][27][28][29][30]. Some FLLs are particularly difficult to diagnose even by biopsy because of their small size (<10 mm) or superficial location (close to liver capsule) [12,15,26].…”
Section: Discussionmentioning
confidence: 99%
“…liver tumours or renal transplant cortical perfusion [11][12][13]. External influences are relevant concerning the reproducible influx of the contrast enhancer from the injection site to the ROI [14,15]. The perfusion in CEUS is calculated as the velocity of contrast saturation.…”
Section: Differences To Existing Methods Of Sonographic Perfusion Evamentioning
confidence: 99%
“…The characteristic features of a TIC analysis are shown in ▶ Fig. 3 [11,41]. This model for quantification of tumor vascularization was applied in multicentric studies validating the AUC as predictive marker [42,43].…”
Section: Enhancement (Degree and Timing)mentioning
confidence: 99%
“…The CEUS "circle of disaster" is characterized by the following criteria: Microbubble destruction → increase in contrast agent dose →attenuation (shadowing) → higher mechanical index → additional microbubble destruction [40,41,58].…”
Section: How To Avoid Artefacts?mentioning
confidence: 99%
See 1 more Smart Citation