Placing Conducting Polymers onto a H-Terminated Si(100) Surface via a Pulse Valve

Abstract: We used a pulse-injection method to fix π-conjugated poly(3-hexylthiophene) (P3HT) molecules onto H-terminated Si(100) surfaces. Isolated molecules of P3HT were observed by scanning tunneling microscopy. The P3HT molecules comprised an almost all-trans conformation, reflecting the rigid feature of molecular chains. By quenching the substrate at 135 K, residual solvent molecules were observed. We could control the surface density of fixed P3HT molecules by changing both or either the volume or concentration of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
55
0

Year Published

2006
2006
2012
2012

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(55 citation statements)
references
References 28 publications
0
55
0
Order By: Relevance
“…26,28 Our Ru2-toluene/Au͑111͒ sample was heated under vacuum at 470 K for 20 min, and the heated sample is shown in Fig. 26,28 Our Ru2-toluene/Au͑111͒ sample was heated under vacuum at 470 K for 20 min, and the heated sample is shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…26,28 Our Ru2-toluene/Au͑111͒ sample was heated under vacuum at 470 K for 20 min, and the heated sample is shown in Fig. 26,28 Our Ru2-toluene/Au͑111͒ sample was heated under vacuum at 470 K for 20 min, and the heated sample is shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…2 was annealed under a hydrogen flame for 10 min; the Au substrates used in Figs. 26,28 Grill et al used temperature programed desorption to show that with diethyl ether as solvent, molecules remain on a Cu͑111͒ surface at room temperature. The clean Au͑111͒ was transferred to a sample preparation chamber with a pulsed valve ͑Parker Instrumentation 9-Series, 0.5 mm nozzle diameter, IOTA One driver͒ installed.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The sample preparation and data collection for the STM investigation were performed as follows: These molecules were suspended in toluene or ethanol depending on the solubility, and initially spun-cast on Au(111) on mica and imaged in an ambient, home-built STM. Following initial investigations in air, the solutions were deposited in high vacuum using a fast-actuating, small orifice solenoid dosing valve [4,5] onto argon-sputtered and annealed Au(111) on mica substrates and imaged using an RHK variable temperature UHV-STM [6]. The dosing technique was chosen over sublimation in vacuum because it appeared in thermal decomposition studies using a thermogravimetric analyzer on related oligo(phenylene ethynylene) (OPE) alkynyl-fullerenes that the fullerene-based wheels began to cleave from the alkynyl-axles at ca.…”
Section: Experiments Andcurrent Resultsmentioning
confidence: 99%