2012
DOI: 10.1016/j.prro.2011.12.003
|View full text |Cite
|
Sign up to set email alerts
|

Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

6
168
0
7

Year Published

2015
2015
2018
2018

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 141 publications
(181 citation statements)
references
References 11 publications
6
168
0
7
Order By: Relevance
“…The former leads to the same result as the unweighted version of our k‐means algorithm; the latter yields the opposite effect of the weighted version by drawing the isocenter toward the larger targets which is undesirable for the sake of minimizing sensitivity to rotations 6, 7, 9, 10. Our k‐means algorithm approach, therefore, can place the isocenter in a manner comparable to a common technique (using the unweighted version) or with the recommended characteristic of being closer to small targets to a degree inversely proportional to their size (using the weighted version).…”
Section: Discussionmentioning
confidence: 95%
See 3 more Smart Citations
“…The former leads to the same result as the unweighted version of our k‐means algorithm; the latter yields the opposite effect of the weighted version by drawing the isocenter toward the larger targets which is undesirable for the sake of minimizing sensitivity to rotations 6, 7, 9, 10. Our k‐means algorithm approach, therefore, can place the isocenter in a manner comparable to a common technique (using the unweighted version) or with the recommended characteristic of being closer to small targets to a degree inversely proportional to their size (using the weighted version).…”
Section: Discussionmentioning
confidence: 95%
“…Other authors have described placing the isocenter in the middle of the target centroids7 or in the middle of a structure representing the Boolean union of all targets 6. The former leads to the same result as the unweighted version of our k‐means algorithm; the latter yields the opposite effect of the weighted version by drawing the isocenter toward the larger targets which is undesirable for the sake of minimizing sensitivity to rotations 6, 7, 9, 10.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…1). All IMRT cases used seven to nine beams and RapidArc cases used two arcs, except for the SIMT case, which used four arcs, with dose optimization constraints that follow the technique of Clark et al (29) . Point dose measurement using an ion chamber (PTW PinPoint Chamber, Model 31014) and planar dose distribution measurement using films (Gafchromic EBT3) were performed in both the high‐dose target and a low‐dose region.…”
Section: Methodsmentioning
confidence: 99%