2007
DOI: 10.1080/03630260701587745
|View full text |Cite
|
Sign up to set email alerts
|

Plasma and Urine Hydroxyurea Levels Might be Useful in the Management of Adult Sickle Cell Disease

Abstract: Hydroxyurea (HU) is useful for treating sickle cell anemia because of its ability to reduce some of the severe clinical events such as painful crises and acute chest syndrome. It may also reduce the need for blood transfusions and frequent hospitalizations and reduce mortality. Nevertheless, no consistent recommendations regarding its therapeutic schedule are defined. Our aim was to improve and validate a high performance liquid chromatography (HPLC) technique to measure HU and to study HU levels in serum and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
39
0
1

Year Published

2009
2009
2019
2019

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 30 publications
(40 citation statements)
references
References 15 publications
0
39
0
1
Order By: Relevance
“…Thus, the quantification method of hydroxyurea in human plasma by UPLC with diode detector (UV) was developed in order to follow up patients treated with this drug. It was developed from the methods of Manouilov et al (1998) and Bachir et al (2007) and is based on the formation of a color reaction between hydroxyurea and solutions A (thiosemicarbazide + sodium chloride + diacetyl monoxime) and B (sulfuric acid + phosphoric acid + ferric chloride) (Manouilov, McGuire, Gwilt et al, 1998;Bachir et al, 2007).…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Thus, the quantification method of hydroxyurea in human plasma by UPLC with diode detector (UV) was developed in order to follow up patients treated with this drug. It was developed from the methods of Manouilov et al (1998) and Bachir et al (2007) and is based on the formation of a color reaction between hydroxyurea and solutions A (thiosemicarbazide + sodium chloride + diacetyl monoxime) and B (sulfuric acid + phosphoric acid + ferric chloride) (Manouilov, McGuire, Gwilt et al, 1998;Bachir et al, 2007).…”
Section: Discussionmentioning
confidence: 99%
“…A wavelength of 440 nm was identified as having the highest absorption. To choose the best mobile phase, adjustments were made in the proportions of acetonitrile/water, and the analysis time obtained was of 13 min, a reduction of 50% compared to the method of Bachir et al (2007), which used 16.7% acetonitrile (Bachir et al, 2007).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations