2005
DOI: 10.1016/s1885-5857(06)60489-1
|View full text |Cite
|
Sign up to set email alerts
|

Plasma Concentration of Big Endothelin-1 and Its Relation With Plasma NT-proBNP and Ventricular Function in Heart Failure Patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
8
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(10 citation statements)
references
References 40 publications
2
8
0
Order By: Relevance
“…On the one hand, the present results are in keeping with previous reports [14,15] showing that ET-1 levels were increased in PH patients, which may contribute to the synthesis and release of these peptides in cardiac tissues [23,24]. The positive correlation between ET-1 and N-BNP has been demonstrated [25]. We confirmed this correlation in IPAH patients.…”
Section: Discussionsupporting
confidence: 93%
“…On the one hand, the present results are in keeping with previous reports [14,15] showing that ET-1 levels were increased in PH patients, which may contribute to the synthesis and release of these peptides in cardiac tissues [23,24]. The positive correlation between ET-1 and N-BNP has been demonstrated [25]. We confirmed this correlation in IPAH patients.…”
Section: Discussionsupporting
confidence: 93%
“…Increased big ET-1 concentrations are associated with increased ventricular dysfunction [48]. In patients with acute myocardial infarction, ET-1 showed a significant positive correlation with BNP (r = 0.48, P < .0001) [49].…”
Section: Discussionmentioning
confidence: 90%
“…The final effect in terms of muscular tonus of capillary vessels is the result of many different factors, which often oppose one another. Although the mechanism of their interactions is not completely clear, ET-1 is an essential regulator of muscular tonus of capillary vessels and should not be treated simply as a marker of severe sepsis [48,49].…”
Section: Discussionmentioning
confidence: 99%
“…Big ET-1 is more stable than ET-1 as it has a longer halflife and it is cleared slowly from the circulation [36,41]. Thus, big ET-1 is considered to be a sensitive measure of endothelin system activation [41].…”
Section: Discussionmentioning
confidence: 99%
“…Big ET-1 is more stable than ET-1 as it has a longer halflife and it is cleared slowly from the circulation [36,41]. Thus, big ET-1 is considered to be a sensitive measure of endothelin system activation [41]. Given that the high circulating level of ET-1 is mainly attributed to the release of big ET-1 [36,41], we measured big ET-1 in our breast cancer patients with relative LVH and healthy control women.…”
Section: Discussionmentioning
confidence: 99%