Plasma processes to detect fluorine with ICPMS/MS as [M–F]+: an argument for building a negative mode ICPMS/MS

Abstract: The paper describes that the 2nd ionisation potential and the difference in bond energy of a metal to fluorine bond and of a metal to oxygen bond are the most important parameters to form a metal fluoride ion for the detection of fluorine in ICPMS/MS.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
29
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 33 publications
(30 citation statements)
references
References 14 publications
(2 reference statements)
1
29
0
Order By: Relevance
“…[22][23][24] High-resolution equipment 22 can also be a suitable option to overcome spectral interferences in halogen determination, combining high sensitivity with low background signals and providing low LODs. 24 For example, this technique is suitable for determination of 35 Cl + at medium resolution (m/Δm = 4000) except in the presence of significant quantities of 70 Zn 2+ and 70 Ge 2+ . 22 Using high-resolution mode (m/Δm = 10000), 37 Cl + determination free of 36 Ar 1 H + interference has also been possible.…”
Section: Halogen Determination By Icp-msmentioning
confidence: 99%
See 4 more Smart Citations
“…[22][23][24] High-resolution equipment 22 can also be a suitable option to overcome spectral interferences in halogen determination, combining high sensitivity with low background signals and providing low LODs. 24 For example, this technique is suitable for determination of 35 Cl + at medium resolution (m/Δm = 4000) except in the presence of significant quantities of 70 Zn 2+ and 70 Ge 2+ . 22 Using high-resolution mode (m/Δm = 10000), 37 Cl + determination free of 36 Ar 1 H + interference has also been possible.…”
Section: Halogen Determination By Icp-msmentioning
confidence: 99%
“…32 In addition, even considering a better sensitivity for this species, 138 Ba 19 F + (m/z 157) is still susceptible to polyatomic and isobaric interferences, such as from 157 Gd + and 138 Ba 18 O 1 H + , and is also highly matrix dependent. 35,36 Therefore, it is still necessary to perform a mass-shift approach in order to guarantee BaF + determination free of spectral interferences by ICP-MS. 32,34,37 With this objective, both NH 3 25 and O As an alternative strategy for fluorine determination by ICP-MS, a method using a quadrupole instrument operating in negative mode has been developed. 35,36 By making some adjustments to the nebulizer gas flow rate (0.60-0.70 L min −1 ), fluorine determination was performed in standard solution and the LOD was 400 ng mL −1 .…”
Section: Isobaric and Polyatomic Interferences Related To Halogen Dmentioning
confidence: 99%
See 3 more Smart Citations