Platelet reduction after stentless pericardial aortic valve replacement

Abstract: The aim of the study was to investigate the multi-factorial phenomenon of possible postoperative thrombocytopenia after aortic valve replacement (AVR) with the freedom SOLO (FS) bioprosthesis. A total of 254 patients underwent AVR with FS bioprosthesis in two cardiac surgery institutes. Platelet counts were measured preoperatively, immediately postoperatively and daily until the 11th day postoperatively. A multivariate generalized estimating equation model was applied to identify prognostic factors for whether… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 9 publications
1
14
0
Order By: Relevance
“…Clearly some mechanistic link exists between high‐velocity aortic lesions and TP. Not only have TP and hemolysis been reported with severe aortic valvular stenosis but others suggest that smaller pre‐operative valve areas increase the risk of having post‐operative TP . However, to date no systematic examination of native anatomic and/or dynamic aortic valvular properties has been undertaken.…”
Section: Discussionmentioning
confidence: 99%
“…Clearly some mechanistic link exists between high‐velocity aortic lesions and TP. Not only have TP and hemolysis been reported with severe aortic valvular stenosis but others suggest that smaller pre‐operative valve areas increase the risk of having post‐operative TP . However, to date no systematic examination of native anatomic and/or dynamic aortic valvular properties has been undertaken.…”
Section: Discussionmentioning
confidence: 99%
“…Postoperative platelet counts were extracted from 11 studies (n ¼ 1,015) and compared with their preoperative value [22][23][24][25][26][27][28][29][30][31][32]. A control group was created using postoperative platelet counts from all other aortic valve prostheses included in these 11 studies (n ¼ 1,090).…”
Section: Thrombocytopeniamentioning
confidence: 99%
“…On average, platelet counts in the other aortic prostheses were back to their preoperative level on postoperative day 9. Of the 11 articles shown in Figure 3, 10 concluded that thrombocytopenia was a numeric phenomenon with no adverse clinical events [22][23][24][25][26][27][28][29][30][31]. However, Hirnle and colleagues [32] reported 1 death in 29 Freedom SOLO patients due to thrombotic thrombocytopenic purpura.…”
Section: Thrombocytopeniamentioning
confidence: 99%
See 1 more Smart Citation
“…It seems unrelated to the type of aortic bioprosthesis and I have not observed this phenomenon only in stentless pericardial valves, but also in different bioprostheses [68]. However, thrombocytopenia after implantation of the stentless pericardial xenografts can develop more common and becomes dangerous for the patient [69,70].…”
Section: Concomitant Hematologic Diseasementioning
confidence: 99%