Polarization preservation in diffusive scattering from in vivo turbid biological media: effects of tissue optical absorption in the exact backscattering direction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
29
0

Year Published

2002
2002
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(30 citation statements)
references
References 20 publications
1
29
0
Order By: Relevance
“…13 Vitkin et al have demonstrated in vivo that light that is diffusively scattered by human skin retains significant polarization in exact backscattering directions, and the degree of polarization increases with increased absorption. 14 Sankaran et al have investigated the degree of polarization in five porcine tissues (fat, tendon, blood, myocardium muscle, and artery) of different thicknesses (0.1 to 2 mm) in transmission geometry. They have shown that the Rayleigh-scattering regime is dominant for all the tissues except blood, with the degree of linear polarization exceeding the degree of circular polarization.…”
Section: Introductionmentioning
confidence: 99%
“…13 Vitkin et al have demonstrated in vivo that light that is diffusively scattered by human skin retains significant polarization in exact backscattering directions, and the degree of polarization increases with increased absorption. 14 Sankaran et al have investigated the degree of polarization in five porcine tissues (fat, tendon, blood, myocardium muscle, and artery) of different thicknesses (0.1 to 2 mm) in transmission geometry. They have shown that the Rayleigh-scattering regime is dominant for all the tissues except blood, with the degree of linear polarization exceeding the degree of circular polarization.…”
Section: Introductionmentioning
confidence: 99%
“…Our estimations give us that the value of y varied in the range of 0.7-1.8 (except one point, where r ≈ 0.1) in the experiment of Vitkin and Studinski (10). We derived this result from their Fig.…”
Section: Relationship Between the Degree Of Polarization And The Diffmentioning
confidence: 94%
“…Traditional way to measure blood sugar level needs to prick finger to get blood, which is painful, potentially dangerous and expensive to operate. In recent ten years many non-invasive methods [3][4][5][6][7][8] have been studied to measure blood sugar level. The non-invasive methods are fast, painless, safe and convenient, but the measurement accuracy is still a barrier due to the weak signal from blood and interference of other blood components.…”
Section: Introductionmentioning
confidence: 99%