2024
DOI: 10.1039/d3tb02070c
|View full text |Cite
|
Sign up to set email alerts
|

Polyarylether-based COFs coordinated by Tb3+ for the fluorescent detection of anthrax-biomarker dipicolinic acid

Yinsheng Liu,
Mingyue Wang,
Yinfei Hui
et al.

Abstract: In this study, a rare-earth hybrid luminescent material (lanthanide@COF) was constructed for the detection of a biomarker for anthrax (dipicolinic acid, DPA).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2024
2024
2025
2025

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 44 publications
0
4
0
Order By: Relevance
“…However, the LUMO of GC-TFPB-AO (−4.69 eV) is lower than that of UO 2 2+ (−4.24 eV), which implies that the excited-state electrons in GC-TFPB-AO are not conducive to transferring to the LUMO level of UO 2 2+ , thus precluding the occurrence of PET between them (Figure d) . Moreover, the HOMO of GC-TFPB-AO is slightly higher than the HOMO level of UO 2 2+ , suggesting that the electrons in the HOMO level of GC-TFPB-AO can be transferred to UO 2 2+ by non-photo-excited means, which can lead to the ICT quenching. …”
Section: Resultsmentioning
confidence: 97%
“…However, the LUMO of GC-TFPB-AO (−4.69 eV) is lower than that of UO 2 2+ (−4.24 eV), which implies that the excited-state electrons in GC-TFPB-AO are not conducive to transferring to the LUMO level of UO 2 2+ , thus precluding the occurrence of PET between them (Figure d) . Moreover, the HOMO of GC-TFPB-AO is slightly higher than the HOMO level of UO 2 2+ , suggesting that the electrons in the HOMO level of GC-TFPB-AO can be transferred to UO 2 2+ by non-photo-excited means, which can lead to the ICT quenching. …”
Section: Resultsmentioning
confidence: 97%
“…Two smaller Eu 3d 5/2 and Eu 3d 3/2 peaks were observed at 1125.2 eV and 1155.8 eV, respectively, attributed to the Eu 2+ oxidation state [46,47]. The corresponding O 1s XPS profiles were deconvoluted into three peaks of 531.6 eV, 532.1 eV, and 533.6 eV, among which the peak at 533.6 eV was associated with C-OH bonds, the peak at 532.6 eV was ascribed to Tb-O bonds, and the peak located at 531.6 eV came from Eu-O bonds [48,49]. The above results all indicated the successful preparation of Tb-Eu-TCPP.…”
Section: Resultsmentioning
confidence: 99%
“…Fluorescence analysis technology has received tremendous attention in disease diagnosis, food inspection, and environmental monitoring due to the merits of high sensitivity, high reproducibility, simplicity and easy integration. 8,9 A large number of fluorescent probes have been reported for DPA detection, such as lanthanide ionbased metal-organic frameworks, 1,10 boron carbon oxynitride quantum dots, 11 carbon dots, 12 covalent organic frameworks, 13 SiO 2 nanoparticles, 14 europium-organic gels nanosheets, 15 and so on. Recently, ratiometric fluorescence methods relying on a reference signal and a response signal have been popular due to their self-calibration, higher accuracy, higher precision, and visualization effect.…”
Section: Introductionmentioning
confidence: 99%