2022
DOI: 10.1016/j.talanta.2022.123693
|View full text |Cite
|
Sign up to set email alerts
|

Polydopamine inner wall-coated hypodermic needle as microextraction device and electrospray emitter for the direct analysis of illicit drugs in oral fluid by ambient mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 58 publications
0
11
0
Order By: Relevance
“…The voltage spray was set at 5 kV; the tube lens voltage was 130 V, and the capillary voltage and temperature were 35 V and 275 °C, respectively. The distance between the needle tip and the MS inlet was maintained at 10 mm, according to previous results . The m / z precursor → product ion transitions employed for quantification using 30 V as the collision energy were 315.3 → 193.1 and 318.3 → 196.1 for THC and THC- d 3 , respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The voltage spray was set at 5 kV; the tube lens voltage was 130 V, and the capillary voltage and temperature were 35 V and 275 °C, respectively. The distance between the needle tip and the MS inlet was maintained at 10 mm, according to previous results . The m / z precursor → product ion transitions employed for quantification using 30 V as the collision energy were 315.3 → 193.1 and 318.3 → 196.1 for THC and THC- d 3 , respectively.…”
Section: Methodsmentioning
confidence: 99%
“…used a hypodermic needle with a polydopamine (PDA)-coated inner wall as a microextraction and electrospray device to detect methamphetamine, methadone and cocaine in saliva. 40 The PDA film inside the technique for the rapid analysis of drugs in hair samples. 41 In this technique, a single hair is placed on a metal ceramic heater and a high voltage and solvent are added to the sample.…”
Section: Kim Et Al Used Sfpesi For the Rapid Detection Of Cocaine Met...mentioning
confidence: 99%
“…used a hypodermic needle with a polydopamine (PDA)‐coated inner wall as a microextraction and electrospray device to detect methamphetamine, methadone and cocaine in saliva. 40 The PDA film inside the needle allows for the rapid extraction of analytes at an alkaline pH, then eluted in a methanol‐based ESI solution for ionization. The study presents a cheap and disposable extraction/ionization probe with an overall analysis time of 3 min per sample.…”
Section: Applications Of Aimsmentioning
confidence: 99%
“…A very smart approach was recently proposed by Cárdenas and Lucena's research group [32]. The sorbent material is deposited in the inner walls of a needle and the sample is repeatedly aspirated and dispensed through the needle.…”
Section: Miniaturization Of Sorbent‐based Approachesmentioning
confidence: 99%
“…(B) Manifold used for the direct ambient mass spectrometry analysis using a needle as an extraction device. Reproduced with permission [25] and [32], respectively.…”
Section: Solid-phase Microextractionmentioning
confidence: 99%