2015
DOI: 10.1016/j.electacta.2015.02.207
|View full text |Cite
|
Sign up to set email alerts
|

Polyelectrolyte functionalized gold nanoparticles-reduced graphene oxide nanohybrid for electrochemical determination of aminophenol isomers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 56 publications
(13 citation statements)
references
References 39 publications
0
13
0
Order By: Relevance
“…Undoubtedly, the developed manganese silicate‐modified electrode was quite qualified for the simultaneous detection of trace levels of 2‐AP and 4‐AP. Compared with mostly reported electrochemical sensors that are listed in Table 1 1727, we clearly find that the newly‐developed method exhibits higher sensitivity.…”
Section: Introductionmentioning
confidence: 69%
See 2 more Smart Citations
“…Undoubtedly, the developed manganese silicate‐modified electrode was quite qualified for the simultaneous detection of trace levels of 2‐AP and 4‐AP. Compared with mostly reported electrochemical sensors that are listed in Table 1 1727, we clearly find that the newly‐developed method exhibits higher sensitivity.…”
Section: Introductionmentioning
confidence: 69%
“…Therefore, both of the oxidation of 2‐AP and 4‐AP are two‐electron reaction. Combining the conclusion from the pH effect that the number of protons and electrons take part in the electrochemical reaction is 1:1, so the electrochemical mechanism for 2‐AP and 4‐AP at manganese silicate/GCE can be assumed according to the literatures 17, 19: …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The prepared composite was dispersed and placed onto an Au electrode by drop-casting in order to develop a voltammetric sensor for dopamine. Li et al [109] showed that aminophenol isomers can be easily detected by differential pulse voltammetry using a GCE decorated with AuNPs and an rGO composite coated with PDDA. The composite was prepared by the sequential thermal reductions of GO and AuCl 4 − in the presence of PDDA.…”
Section: Sensing Film Comprising Me or Meo Npsmentioning
confidence: 99%
“…EIS measurement was carried out in 0.1 M PBS containing 500 µM ETB over a frequency range of 0.1 Hz to 10 5 Hz with the AC signal amplitude of 10 mV, Figure 2. Generally, the Nyquist plot of the EIS is characterized by two important regions: a semicircular region at a higher frequency corresponding to the electron-transfer-limited process and a linear portion at low frequency region featuring diffusion limited process [20,21]. The diameter of the semicircular portion is equivalent to the charge transfer resistance (R ct ).…”
Section: Electrochemical Impedance Spectroscopy (Eis)mentioning
confidence: 99%