2022
DOI: 10.1016/j.gie.2021.12.020
|View full text |Cite
|
Sign up to set email alerts
|

Polyp detection and false-positive rates by computer-aided analysis of withdrawal-phase videos of colonoscopy of the right-sided colon segment in a randomized controlled trial comparing water exchange and air insufflation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 52 publications
0
8
0
Order By: Relevance
“…In a study of video recordings of an RCT, artificial intelligence (computer‐aided detection) showed a significantly higher additional polyp detection rate and a lower number of false positives per colonoscopy (related to feces and bubbles) in the WE group compared with the air‐insufflation group. The analysis supported the hypothesis that the strengths of computer‐aided detection and WE complemented the weaknesses of each other in optimizing polyp detection 11 . The listing of WAC continued in the GIE Editorial Board top 10 topics: advances in GI endoscopy in 2020 12 .…”
Section: Discussionmentioning
confidence: 53%
See 3 more Smart Citations
“…In a study of video recordings of an RCT, artificial intelligence (computer‐aided detection) showed a significantly higher additional polyp detection rate and a lower number of false positives per colonoscopy (related to feces and bubbles) in the WE group compared with the air‐insufflation group. The analysis supported the hypothesis that the strengths of computer‐aided detection and WE complemented the weaknesses of each other in optimizing polyp detection 11 . The listing of WAC continued in the GIE Editorial Board top 10 topics: advances in GI endoscopy in 2020 12 .…”
Section: Discussionmentioning
confidence: 53%
“…The analysis supported the hypothesis that the strengths of computer-aided detection and WE complemented the weaknesses of each other in optimizing polyp detection. 11 The listing of WAC continued in the GIE Editorial Board top 10 topics: advances in GI endoscopy in 2020. 12 The use of on-demand sedation with WE reduced the insertion pain score, 13 lowered the dose of sedation medication, and shortened the recovery time.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, Tang et al 37 reported that the water exchange insertion method has the potential to reduce FP through salvage cleaning of feces and bubbles during insertion. However, we believe that, unlike endoscopic techniques, updating the system is a fundamental solution to FP and is directly related to the results.…”
Section: Discussionmentioning
confidence: 99%