2019
DOI: 10.1109/tcst.2017.2761866
|View full text |Cite
|
Sign up to set email alerts
|

Port-Controlled Phasor Hamiltonian Modeling and IDA-PBC Control of Solid-State Transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
52
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(52 citation statements)
references
References 27 publications
0
52
0
Order By: Relevance
“…The space Equations (18) are called the "perturbed Port-Hamiltonian model" of a physical system [13][14][15][16]21,29,35] for the αβ or dq frames because we can substitute (17) in (18). The vector of the input variables m αβ,dq and the vector of disturbance variables d αβ,dq is Equation (19).…”
Section: In Balanced Systems the Neutral Voltagementioning
confidence: 99%
See 2 more Smart Citations
“…The space Equations (18) are called the "perturbed Port-Hamiltonian model" of a physical system [13][14][15][16]21,29,35] for the αβ or dq frames because we can substitute (17) in (18). The vector of the input variables m αβ,dq and the vector of disturbance variables d αβ,dq is Equation (19).…”
Section: In Balanced Systems the Neutral Voltagementioning
confidence: 99%
“…A passivity-based controller [13][14][15][16][17][18] was developed using an interconnection and damping assignment (IDA-PBC), which enables the control of a three-phase inverter to be decoupled in the dq frame [27][28][29]. For the presented inverter model cases, we assume that the coefficients of the matrixes J αβ,dq , R αβ,dq , G αβ,dq , and D αβ,dq do not depend on the state variables.…”
Section: Three-phase Voltage Source Inverter Controller Designmentioning
confidence: 99%
See 1 more Smart Citation
“…When using the state space averaging equations, which characterize the boost converter (13) and linearizing around an operating point we obtain (26).…”
Section: Local Dynamics Assignment -Small Signal and Tuningmentioning
confidence: 99%
“…Previous studies of this problem propose different solutions to minimize the presence of reactive power in the Electric Distribution System [22][23][24][25][26][27][28][29][30], as well as to minimize the costs generated by its presence [31,32]. Traditionally, according to these studies, the presence of reactive power is exclusively associated with the presence of the elements mentioned above.…”
Section: Introductionmentioning
confidence: 99%