1974
DOI: 10.1088/0305-4608/4/1/001
|View full text |Cite
|
Sign up to set email alerts
|

Positron annihilation gamma ray lineshapes in metals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1976
1976
2008
2008

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…The irradiated region in the center of the samples has been investigated with laterally resolved Doppler broadening (DB) measurements in order to image the ion beam spot. Although the trapping rate of positrons in Mg is rather small and the trapping sites are shallow, 5,19,20 the ion beam spot on the samples has been clearly reproduced within the spatial resolution of the CDBS-facility. As expected from simulations with the program SRIM, which was used to calculate the ion and vacancy distribution, the Doppler broadening of the annihilation line depends significantly on the positron penetration depth, which was adjusted up to 5.5 µm.…”
Section: Discussionmentioning
confidence: 87%
See 3 more Smart Citations
“…The irradiated region in the center of the samples has been investigated with laterally resolved Doppler broadening (DB) measurements in order to image the ion beam spot. Although the trapping rate of positrons in Mg is rather small and the trapping sites are shallow, 5,19,20 the ion beam spot on the samples has been clearly reproduced within the spatial resolution of the CDBS-facility. As expected from simulations with the program SRIM, which was used to calculate the ion and vacancy distribution, the Doppler broadening of the annihilation line depends significantly on the positron penetration depth, which was adjusted up to 5.5 µm.…”
Section: Discussionmentioning
confidence: 87%
“…Also the diameter of the irradiated area matches the size of the ion beam of 5 mm within the spatial resolution of the CDB-spectrometer. Although the trapping rate of positrons in Mg is rather small and the trapping sites are shallow, 5,19,20 the ion beam spot on the samples has been clearly reproduced.…”
Section: B Laterally Resolved Db-measurements -S(xy)mentioning
confidence: 90%
See 2 more Smart Citations
“…Since positrons are not very efficiently trapped in magnesium due to the shallow trapping sites [12][13][14], the respective investigations were demanding. Therefore, the CDBS is currently equipped with a 4 K cryostat in order to cool the sample and hence increasing the trapping rate.…”
Section: Introductionmentioning
confidence: 99%