Potentiometric Biosensor Based on Artificial Antibodies for an Alzheimer Biomarker Detection

Abstract: This paper presents a potentiometric biosensor for the detection of amyloid β-42 (Aβ-42) in point-of-care analysis. This approach is based on the molecular imprint polymer (MIP) technique, which uses covalently immobilised Aβ-42 to create specific detection cavities on the surface of single-walled carbon nanotubes (SWCNTs). The biosensor was prepared by binding Aβ-42 to the SWCNT surface and then imprinting it by adding acrylamide (monomer), N,N’-methylene-bis-acrylamide (crosslinker) and ammonium persulphate … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 79 publications
0
4
0
Order By: Relevance
“…Before polymerization, the carbon nanotubes were oxidized to provide reactive points for the covalent immobilization of β-amyloid 1-42. The imprinting step yielded imprinted carbon nanotubes that were afterward embedded in PVC membranes deposited on a graphite electrode [90]. Both studies proved good selectivity for β-amyloid 1-42 in plasma.…”
Section: Neurodegenerative Diseasesmentioning
confidence: 94%
“…Before polymerization, the carbon nanotubes were oxidized to provide reactive points for the covalent immobilization of β-amyloid 1-42. The imprinting step yielded imprinted carbon nanotubes that were afterward embedded in PVC membranes deposited on a graphite electrode [90]. Both studies proved good selectivity for β-amyloid 1-42 in plasma.…”
Section: Neurodegenerative Diseasesmentioning
confidence: 94%
“…Field-effect transistors (FETs) form the basis of many potentiometric devices. It is commonly used to detect changes in pH, ion concentrations, and the rate of enzyme-catalyzed biocatalytic reactions [129].…”
Section: Potentiometric Biosensorsmentioning
confidence: 99%
“…A standard graph is obtained by determining the values of the various concentrations of the substance to be studied. The range in which linear increase is observed in graphic interpretation is determined as the measurement range [95].…”
Section: Linear Measurement Rangementioning
confidence: 99%
“…Repeatability is observed by calculating the variation coefficients and standard deviations of the values taken [94]. As a result of the measurements made, it is determined whether the standard deviation and variation coefficients calculated, and the biosensors are reusable [95]. The variation coefficient must be less than 5% to prove that the biosensor system is workable [58].…”
Section: Repeatabilitymentioning
confidence: 99%