2020
DOI: 10.1016/j.jpowsour.2020.228075
|View full text |Cite
|
Sign up to set email alerts
|

Power quality and reactive power of water electrolyzers supplied with thyristor converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
27
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(28 citation statements)
references
References 15 publications
1
27
0
Order By: Relevance
“…This system consists of a delta-star transformer and an AC-DC rectifier interfacing the grid system and PEMEL. Since the current of the electrolyzer must be controlled, thyristors-based rectifiers are generally preferred for this purpose [8][9][10]. In Figure 10, a 6-pulse thyristor bridge rectifier is shown.…”
Section: Ac-dc and Dc-dc Convertersmentioning
confidence: 99%
See 3 more Smart Citations
“…This system consists of a delta-star transformer and an AC-DC rectifier interfacing the grid system and PEMEL. Since the current of the electrolyzer must be controlled, thyristors-based rectifiers are generally preferred for this purpose [8][9][10]. In Figure 10, a 6-pulse thyristor bridge rectifier is shown.…”
Section: Ac-dc and Dc-dc Convertersmentioning
confidence: 99%
“…Currently, thyristor-based rectifiers are particularly employed for industrial and power-to-gas applications where a high voltage and current are required to supply electrolyzers. In [8][9][10], 6-pulse and 12-pulse thyristors-based rectifiers connected to alkaline electrolyzers have been investigated In low-power wind turbines with a PMSG, the three-phase high-frequency semicontrolled rectifier, shown in Figure 7, is attractive, since it is simple and robust. Moreover, all active switches are connected to a common point, and a short-circuit through a leg is not possible.…”
Section: Ac-dc and Dc-dc Convertersmentioning
confidence: 99%
See 2 more Smart Citations
“…In the inner processes of P2G stations, it is the first step that the alternating current is converted to the direct current which is used for electrolysis. The rectifier in P2G stations is usually based on thyristors, and hence, the reactive power consumption of P2G is coupled with the active power consumption [37]. However, few works have considered the reactive power consumption of P2G in the operation of the IPGDS, which may cause security risks and unreliable economic assessment.…”
Section: Introductionmentioning
confidence: 99%