2021
DOI: 10.1109/access.2021.3129096
|View full text |Cite
|
Sign up to set email alerts
|

Power Quality Enhancement Using Dynamic Voltage Restorer (DVR)-Based Predictive Space Vector Transformation (PSVT) With Proportional Resonant (PR)-Controller

Abstract: In the power distribution system, the Power Quality (PQ) is disturbed by the voltage sag and swells. The Dynamic Voltage Restorer (DVR) is used to enhance various PQ problems like voltage sag, swells, and Harmonics. The previous Intrinsic Space Vector Transformation (ISVT) control techniques with DVR system, to compensate the power quality issue. It produced a steady-state error, low efficiency, and high THD. The SMES based DVR has provided excellent results in overcoming these issues. The energy is stored by … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 18 publications
0
12
0
Order By: Relevance
“…Preliminary research was carried out on DVR without DC-link before 1996 [84]. A few developments in this topology were reported in [85][86][87] after the development of bidirectional switch escalating the progress of AC-AC converter-based DVR [88]. According to the nature of voltage sags, a control scheme is proposed to compensate for the sag with phase jump in [89].…”
Section: Energy Storagementioning
confidence: 99%
See 1 more Smart Citation
“…Preliminary research was carried out on DVR without DC-link before 1996 [84]. A few developments in this topology were reported in [85][86][87] after the development of bidirectional switch escalating the progress of AC-AC converter-based DVR [88]. According to the nature of voltage sags, a control scheme is proposed to compensate for the sag with phase jump in [89].…”
Section: Energy Storagementioning
confidence: 99%
“…In addition to mitigating the sag and swelling, the DVR can execute other functions such as compensation of selective voltage harmonics [86,270,271], mitigation of voltage flickers [272][273][274], reactive power compensation [275], and frequency compensation [276]. Protection of the DVR [277] is very important during the fault at the load side of the DVR; otherwise, the same downstream fault current is present in the DVR, and it may damage the DVR.…”
Section: Hybrid MLI Topologiesmentioning
confidence: 99%
“…Nowadays, power quality is considered as a major issue in industrial sectors because of increasing sensitive loads [1,2]. In general, the power quality problems greatly affect the distribution side which results in malfunctioning and failure of sensitive loads [3]. Majority of power quality issues are caused by nonlinear loads and harmonic imbalances [4].…”
Section: Introductionmentioning
confidence: 99%
“…Another approach based on the smart branch controller was adopted to compensate for various disturbances in the power quality. The elimination of harmonics is performed without any filter, but the smart branch controller generates nonlinearity in the circuit [56][57][58][59][60]. Fuzzy logic-based compensation is also adopted to improve the power quality; however, the validation requires extensive testing with a hardware setup [61].…”
Section: Introductionmentioning
confidence: 99%