Power Quality Issues Concerning Photovoltaic Generation in Distribution Grids

Abstract: Unregulated utilization of renewable generation including residential photovoltaic (PV) systems can have a significant impact on load characteristics in distribution networks. For improving PV generation capabilities, power quality aspects have to be coordinated with present load characteristics. This paper discusses the harmonic content of PV generation and the influence to power quality indicators in residential distribution networks. PV generation measurement results including current harmonic amplitude and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 13 publications
1
9
0
Order By: Relevance
“…As shown in Figure 19, the THDV reached values up to 2.81% (THDV PVS O f f (1) ) and 3.92% (THDV PVS On(1,2) ) for without and with PV injection for Phase A, both with lowest load power interval (0-2.5%). That means that low-load and low-PV injection conditions had a significant influence on the THDV, which indicates that THDV decreased as the PV injection increased and agreed with the results of Niitso et al [13], Ahmed et al [17], and Grycan et al [18]. However, THDV values were always lower than the 8% limit ( Table 2).…”
Section: Probability Of Occurrence Of Each Scenariosupporting
confidence: 88%
See 3 more Smart Citations
“…As shown in Figure 19, the THDV reached values up to 2.81% (THDV PVS O f f (1) ) and 3.92% (THDV PVS On(1,2) ) for without and with PV injection for Phase A, both with lowest load power interval (0-2.5%). That means that low-load and low-PV injection conditions had a significant influence on the THDV, which indicates that THDV decreased as the PV injection increased and agreed with the results of Niitso et al [13], Ahmed et al [17], and Grycan et al [18]. However, THDV values were always lower than the 8% limit ( Table 2).…”
Section: Probability Of Occurrence Of Each Scenariosupporting
confidence: 88%
“…Thus, a scenario matrix is a tool to analyse data obtained for different instants with similar PV power and power demand conditions. In a manner slightly similar to this proposal, some studies evaluate the indicators, taking into account the level of PV injection [13,19]; other studies compare of parameters during PV injection with standards [10,11,14,18] or compared average, maximum, or minimum values of indices for two conditions: with and without PV injection [9,[15][16][17]20]. The scenario matrix was created as follows:…”
Section: Data Classification Into Scenario Matrixmentioning
confidence: 99%
See 2 more Smart Citations
“…The single‐ and multi‐events of PQDs are the great cause of controlling sensitivity and damaging of equipment in smart‐grid, distribution, and transmission system …”
Section: Introductionmentioning
confidence: 99%