1992
DOI: 10.1109/57.127010
|View full text |Cite
|
Sign up to set email alerts
|

Practical PCA-DA system for measurement of leakage current pulses on polymer insulators under wet contaminated conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

1996
1996
2014
2014

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 5 publications
0
3
0
1
Order By: Relevance
“…이들의 현상은 이미 보고 되어져왔으며 [6,7,8,9] 그리고 세라믹애자의 경우 핀으로부터 아크가 시작되어 갭 을 향하여 진행되어 진다 [6,10,11,12]. 현수애자는 오손습윤 시 누설전류에 의해 전류밀도가 높은 핀 주변의 전계가 높 아지기 때문에 오손/습윤 복합으로 핀 주변으로부터 미소방 전이 발생 되어지며, 더욱더 습윤한 기체가 가세됨으로 대 전류의 아크방전이 발생 하게된다 [6,9,13]. 또한 여러 연구자 들이 애자의 섬락 발생과 이론적인 모델의 제시 그리고 누 설전류모니터링을 통한 예지방법도 보고되어져 왔다[2, 6, 7, [6,7,8,18,19,22,23].…”
Section: 서 론unclassified
“…이들의 현상은 이미 보고 되어져왔으며 [6,7,8,9] 그리고 세라믹애자의 경우 핀으로부터 아크가 시작되어 갭 을 향하여 진행되어 진다 [6,10,11,12]. 현수애자는 오손습윤 시 누설전류에 의해 전류밀도가 높은 핀 주변의 전계가 높 아지기 때문에 오손/습윤 복합으로 핀 주변으로부터 미소방 전이 발생 되어지며, 더욱더 습윤한 기체가 가세됨으로 대 전류의 아크방전이 발생 하게된다 [6,9,13]. 또한 여러 연구자 들이 애자의 섬락 발생과 이론적인 모델의 제시 그리고 누 설전류모니터링을 통한 예지방법도 보고되어져 왔다[2, 6, 7, [6,7,8,18,19,22,23].…”
Section: 서 론unclassified
“…It is known [1][2][3][4] that, when pollution accumulates on the insulator's surfaces, it absorbs moisture and conducts significant leakage currents under service voltage. These currents produce non-uniform heating on the surface, thus producing dry bands which become bridged by one or more partial arcs.…”
Section: An Alternative Approach To Pollution Monitoringmentioning
confidence: 99%
“…Flash-over on high-voltage insulators caused by the combined action of atmospheric pollution and moisture has become a major problem in transmission and distribution power lines. When the pollution accumulates on the insulators' surfaces, it absorbs moisture and conducts significant leakage current under service voltage [1]. This current, with its non-uniform heating of the insulator surface, produces dry bands which become bridged by one or more partial arcs [2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…At present, the common technique to predict the flashover is by means of analysis of leakage current. It indicates the surges occurring near the current peaks of dry band arcing phenomena [5][6][7][8]. For a given insulator, evolution of leakage waveform depends essentially on the changes occurring at the surface pollution layer and surface wetness of the insulator.…”
Section: Introductionmentioning
confidence: 99%