2019
DOI: 10.11113/mjfas.v15n2019.1006
|View full text |Cite
|
Sign up to set email alerts
|

Pre-drilling and self-drilling pins screw-bone fixation stress interaction analysis induced by uniaxial compression loading

Abstract: A newly designed Uniaxial external fixator which functions as a universal fixator in the application of all types of bone fractures is recently introduced by both Hospital Universiti Kebangsaan Malaysia (HUKM) and Universiti Malaysia Perlis (UniMAP). The Investigation is focused on identifying and measuring the performance in terms of strength or weakness of the fixator that is needed before the application to the human body. Hence, this research was conducted to determine the performance of Uniaxial external … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…Within the realm of bone fracture treatment, virtual Computer Aided Design (CAD) modeling and strength analyses such as ANSYS Workbench V13 have shown immense benefits. The selection of appropriate therapy is contingent on multifarious factors including fracture type and location (Ghiasi, 2017), bone properties [ [18] , [19] , [20] , [21] ], and fixator type [ [21] , [22] , [23] , [24] ].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Within the realm of bone fracture treatment, virtual Computer Aided Design (CAD) modeling and strength analyses such as ANSYS Workbench V13 have shown immense benefits. The selection of appropriate therapy is contingent on multifarious factors including fracture type and location (Ghiasi, 2017), bone properties [ [18] , [19] , [20] , [21] ], and fixator type [ [21] , [22] , [23] , [24] ].…”
Section: Introductionmentioning
confidence: 99%
“…Long bone fractures, constituting one of the prevalent forms of skeletal injury [ 21 , 22 , 25 ], demand careful attention to treatment nuances from stabilizer stiffness to temporal considerations for bone tissue reconstruction [ 26 , 27 ]. Devices such as locking plates exemplify technological integration in bone fusion, allowing for direct intervention at the fracture site [ 25 , [27] , [28] , [29] , [30] ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation