2015
DOI: 10.1021/ja5108595
|View full text |Cite
|
Sign up to set email alerts
|

Pre-Gating Conformational Changes in the ChETA Variant of Channelrhodopsin-2 Monitored by Nanosecond IR Spectroscopy

Abstract: Light-gated ion permeation by channelrhodopsin-2 (ChR2) relies on the photoisomerization of the retinal chromophore and the subsequent photocycle, leading to the formation (on-gating) and decay (off-gating) of the conductive state. Here, we have analyzed the photocycle of a fast-cycling ChR2 variant (E123T mutation, also known as ChETA), by time-resolved UV/vis, step-scan FT-IR, and tunable quantum cascade laser IR spectroscopies with nanosecond resolution. Pregating conformational changes rise with a half-lif… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
77
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
2

Relationship

5
4

Authors

Journals

citations
Cited by 39 publications
(80 citation statements)
references
References 82 publications
3
77
0
Order By: Relevance
“…using a similar spectroscopic assignment as in the resonance Raman study (39). In contrast to bacteriorhodopsin, no light adaption was observed using resonance Raman techniques (20) or visual spectroscopy (12).…”
mentioning
confidence: 69%
“…using a similar spectroscopic assignment as in the resonance Raman study (39). In contrast to bacteriorhodopsin, no light adaption was observed using resonance Raman techniques (20) or visual spectroscopy (12).…”
mentioning
confidence: 69%
“…2C. Bands at 1,762(+), 1,745(+), and 1,737(−) cm −1 are from the terminal C=O of D156 (19,38,39), and bands at 1,728(+) and 1,717(−) cm −1 from E90 (19,40). Noteworthy is that none of the above bands showed a bell-shaped evolution in logarithmic time scale akin to the photocurrents.…”
Section: Resultsmentioning
confidence: 95%
“…Both channels were digitized by picoscopes (4227 Series; PICO Technology, St. Neots, Cambridgeshire, UK) with the first running at a sampling frequency of 250 MHz and the second at 1 MHz. The time-resolution of the detection system, limited by the detector/preamplifier system response time, was determined to be 15 ns (5). A quantity of Biophysical Journal 109(2) 287-297 50,000 pretrigger points were recorded (corresponding to 200 ms and 50 ms, respectively) before the exciting laser flash and were stored as reference intensity.…”
Section: Time-resolved Ir Spectroscopymentioning
confidence: 99%
“…Other groups stated that E90 deprotonates early in the photocycle and plays a direct role in the gating mechanism, a conclusion mostly supported by molecular dynamics simulations (30). While it is evident that electrostatics drive structural changes in proteins and that helix hydration facilitates ion conductance (5,12,30), a general consensus on how the observed proton transfer steps are linked to channel opening and closure, to our knowledge, has not yet been reached.…”
Section: Introductionmentioning
confidence: 96%