2019
DOI: 10.3390/jcm8101732
|View full text |Cite
|
Sign up to set email alerts
|

Pre-, Intra-, and Post-Operative Evaluation of Extraocular Muscle Insertions Using Optical Coherence Tomography: A Comparison of Four Devices

Abstract: OCT (optical coherence tomography) is widely used in ophthalmology and pediatric ophthalmology, but limited research has been done on the use of OCT in strabismus. This study investigates the use of different OCT machines to image rectus muscle insertions pre-, intra-, and post-operatively in pediatric strabismus patients. The OCT machines used in the study were a Bioptigen (Leica Microsystems Inc., Buffalo Grove, IL, USA), Spectralis HRA+OCT with Anterior Segment Module (Heidelberg Engineering, Heidelberg, Ge… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
35
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(35 citation statements)
references
References 31 publications
0
35
0
Order By: Relevance
“…Thirty-one articles were excluded: 19 were not written in English, 9 were review papers, and 3 were ex vivo studies. After full-text evaluation, 82 studies discussing the use of MI-OCT in ophthalmology were included [ 13 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , ...…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Thirty-one articles were excluded: 19 were not written in English, 9 were review papers, and 3 were ex vivo studies. After full-text evaluation, 82 studies discussing the use of MI-OCT in ophthalmology were included [ 13 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , ...…”
Section: Resultsmentioning
confidence: 99%
“…MI-OCT can also play a role in strabismus surgery, in particular, in identifying rectus muscle insertion—which is usually hard to locate in patients who have had previous surgery—and confirming scleral suture passage [ 58 ]. Pihlbald et al compared extraocular muscle (EOM) measurements obtained with different OCT devices with calliper distance measured during strabismus surgery in 19 paediatric patients [ 59 ]. In particular, the OCT devices used were Bioptigen (Leica Microsystems Inc., Buffalo Grove, IL, USA), Spectralis HRA + OCT with Anterior Segment Module (Heidelberg Engineering, Heidelberg, Germany), Visante (Carl Zeiss, Oberkochen, Germany), and Zeiss RESCAN 700.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The study done by Rosetto 12 also included reproduction of OCT readings by a second person. The study conducted by Pihlblad et al 26 in 2019 included pre, intra and postoperative muscle insertion measurements. The different OCT machines used were Bioptigen, Inc. (Leica Microsystems Inc., Buffalo Grove, IL, USA), Spectralis HRA+OCT with Anterior Segment Module (Heidelberg Engineering, Heidelberg, Germany), Visante (Carl Zeiss, Oberkochen, Germany), and Zeiss Rescan 700 (Carl Zeiss, Oberkochen, Germany).…”
Section: Discussionmentioning
confidence: 99%
“…Recent advances in anterior segment optical coherence tomography (AS-OCT) have made it possible to visualize not only the cornea, anterior chamber, and iris but also the extraocular muscles (EOMs) [1][2][3][4][5][6][7][8][9]. However, these reports only involved the evaluation of tomographic images of the EOMs, and most of them were related to muscle insertion.…”
Section: Introductionmentioning
confidence: 99%