2020
DOI: 10.1088/1361-6560/ab8c8f
|View full text |Cite
|
Sign up to set email alerts
|

Precise analysis of the timing performance of Cherenkov-radiator-integrated MCP-PMTs: analytical deconvolution of MCP direct interactions

Abstract: In order to achieve the ultimate goal of reducing coincidence time resolution (CTR) to 10 ps, thus enabling reconstruction-less positron emission tomography, a Cherenkov-radiator-integrated microchannel plate photomultiplier tube (CRI) reaching CTR of sub-50 ps full width at half maximum (FWHM) has been developed. However, a histogram of time differences between a pair of the CRIs shows undesirable side peaks, which are caused by gamma rays directly interacting with the micro channel plates (MCPs). Such direct… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 28 publications
0
7
1
Order By: Relevance
“…Ota et al (2019) furthermore covered the lead glass top surfaces with black tape to avoid reflections and selected only the events with the highest photon count. They acknowledge that the resulting detection efficiency does not yet satisfy the requirements of a clinical PET detector (Ota et al 2020). Nevertheless, their outstanding experimental result shows that the physics of positron annihilation do not prohibit a CRT of 30 ps FWHM.…”
Section: Towards 10 Ps Pet?mentioning
confidence: 99%
“…Ota et al (2019) furthermore covered the lead glass top surfaces with black tape to avoid reflections and selected only the events with the highest photon count. They acknowledge that the resulting detection efficiency does not yet satisfy the requirements of a clinical PET detector (Ota et al 2020). Nevertheless, their outstanding experimental result shows that the physics of positron annihilation do not prohibit a CRT of 30 ps FWHM.…”
Section: Towards 10 Ps Pet?mentioning
confidence: 99%
“…The standard window face plate of the LFMCP-based MCP-PMT (LFMCP-PMT) was replaced with a lead compound glass, which acted as a Cherenkov radiator, using an atomic layer deposition (ALD) technique as in our previous works (Ota et al 2019a(Ota et al , 2020a. Owing to the integration of the Cherenkov radiator, the Cherenkov photons produced in the radiator can be efficiently detected by the photocathode.…”
Section: Lead-free Mcp-based Mcp-pmtmentioning
confidence: 99%
“…In this study, we investigated the timing performance of the LFMCP-PMT and the influence of parameters such as DV 1 and DV 3 for the divider circuit. The timing performance was compared to that of the LGMCP-PMT obtained in our previous work (Ota et al 2020a). In addition, the reduction of direct interaction of the LFMCP to gamma rays is assessed.…”
Section: Experiments and Analysismentioning
confidence: 99%
See 2 more Smart Citations