2021
DOI: 10.1016/j.ijepes.2021.107199
|View full text |Cite
|
Sign up to set email alerts
|

Precise appraisement of the harmonic loads impact on hysteresis losses in a 3-phase HTS transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 30 publications
0
4
0
Order By: Relevance
“…Due to its inherent defects, the constant conduction transformer is di cult to meet the needs of the development of the modern power industry. Research and development of new superconducting transformers, thereby improving the performance of power transformers, has great theoretical research signi cance and practical application value [1,2].…”
Section: Introductionmentioning
confidence: 99%
“…Due to its inherent defects, the constant conduction transformer is di cult to meet the needs of the development of the modern power industry. Research and development of new superconducting transformers, thereby improving the performance of power transformers, has great theoretical research signi cance and practical application value [1,2].…”
Section: Introductionmentioning
confidence: 99%
“…Harmonics have been around since the beginning of the industry, mainly due to the nonlinear reactance of magnetized circuits of transformers, reactors, arc furnaces, and fluorescent lamp ballasts. Harmonics in a symmetric 3phase system usually have odd orders of order like 3, 5, 7, and 9 and their amplitude decreases as their order increases [54], [55]. Complete elimination of harmonics is not possible and it is not the subject of research in harmonic control standards and regulations [56].…”
Section: Raw Materials and Research Methodologymentioning
confidence: 99%
“…With reductions in the size and electricity use of circuit components, transformers become lighter, thinner, and 􀅫lexible; this topic is still under research such as: [1] designed a dry-type transformer using different winding types for applications; an experiment device is large. [2] apply non-linear loads such as recti􀅫iers, electronic phase control, and PWM drives, giving rise to a vastly increased level of harmonics in the power network, simulation magnetic 􀅫lux density (T) distribution result. [3] To satisfy the test requirements of the superconducting cables, a large CICC test facility has been developed at the High Magnetic Field, and the samples are.…”
Section: Literature Reviewmentioning