Predetermined implant positioning by means of a novel guide template technique

Abstract: This paper presents a novel guide template technique for implant placement. In esthetic implant dentistry with its restoration-driven implant placement as well as in complete-arch cases with multiple implants, the precise positioning and angulation of dental implants is crucial for achieving the desired prosthetic results. Difficulties in implant positioning may arise especially with grafted jaws resulting from communication problems between surgeon and prosthodontist. This method may alleviate some of the pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2004
2004
2021
2021

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(21 citation statements)
references
References 8 publications
0
21
0
Order By: Relevance
“…When using semiactive systems, the drill axis is predetermined, and no distortion can occur. 19 The only way to transfer the exact position for each implant, as defined on the software, onto the surgical site is to keep a template in place during the surgical procedure, as is done with the Brånemark Novum technique. Because of the intact mucosa of the alveolar ridge, the template may be precisely positioned during surgery in the patient's mouth at the same position used during the CT examination.…”
Section: Discussionmentioning
confidence: 99%
“…When using semiactive systems, the drill axis is predetermined, and no distortion can occur. 19 The only way to transfer the exact position for each implant, as defined on the software, onto the surgical site is to keep a template in place during the surgical procedure, as is done with the Brånemark Novum technique. Because of the intact mucosa of the alveolar ridge, the template may be precisely positioned during surgery in the patient's mouth at the same position used during the CT examination.…”
Section: Discussionmentioning
confidence: 99%
“…18,19 The pin guide has an intrabony part 2.05 mm in diameter and 8 mm in length; to enhance the guidance, the extrabony part fits the trephine drill used. 18,19 The pin guide has an intrabony part 2.05 mm in diameter and 8 mm in length; to enhance the guidance, the extrabony part fits the trephine drill used.…”
Section: Surgerymentioning
confidence: 99%
“…Some foreign systems that use surgical guide have already been applied domestically [5][6][7][8]. We have developed an original CAD/CAM dental implant placement simulation and surgery support system ''BoneNavi'' by a collaborative work with a dental prostheses fabrication company.…”
Section: Introductionmentioning
confidence: 99%