Premature ventricular contraction–induced polymorphic ventricular tachycardia after leadless pacemaker implantation: A unique adverse effect of leadless pacing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
21
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(22 citation statements)
references
References 6 publications
1
21
0
Order By: Relevance
“…Third, in some cases, patients were discharged within 24 hours. However, complications including early ventricular arrhythmias after placement of a MICRA have been reported . It is the opinion of the authors of this study that inpatient observation of higher risk patients is not only prudent but may be necessary for any number of reasons, including monitoring for the potential for postimplant ventricular arrhythmias.…”
Section: Discussionmentioning
confidence: 85%
“…Third, in some cases, patients were discharged within 24 hours. However, complications including early ventricular arrhythmias after placement of a MICRA have been reported . It is the opinion of the authors of this study that inpatient observation of higher risk patients is not only prudent but may be necessary for any number of reasons, including monitoring for the potential for postimplant ventricular arrhythmias.…”
Section: Discussionmentioning
confidence: 85%
“…4,5 Interestingly, we proceeded with more conservative management unlike the reported cases. [3][4][5] We agree with Amin et al 4 that myocardial local irritation as a result of multiple repositions might play a role in VAs, which in turn might explain a higher impedance and longer paced QTc. Despite the underlying mechanism remains a mystery, the relationship between inflammation and ventricular arrhythmias due to cytokine-mediated myocardial remodeling has been previously published and could justify the efficacy of a conservative strategy.…”
mentioning
confidence: 90%
“…Our hypothesis was that long QT was acquired due to myocardial inflammatory damage and intravenous steroids and overstimulation were empirically used in the treatment leading to a resolution of repolarization abnormalities and premature ventricular contractions ( Figure 1C).The association of Micra implantation with the development of malignant VAs has been reported in three cases to the date, as summarized in supplementary table-1. [3][4][5] In all cases, a temporal connection between the leadless PM implantation and the development of the VAs was established, as patients did not suffer before from either premature ventricular contractions or ventricular tachycardia, and in all of the cases the paced beat played a key role in their development. 4,5 Interestingly, we proceeded with more conservative management unlike the reported cases.…”
mentioning
confidence: 96%
See 1 more Smart Citation
“…The system was extracted successfully, revised with a new device of the same type successfully implanted at a different position in the right ventricle, and the VT resolved. The pro-arrhythmic effect of the leadless pacemaker remains to be elucidated, but it may involve the irritation of the right-ventricular myocardium at the site of implantation [27].…”
Section: Other Safety Issuesmentioning
confidence: 99%