2021
DOI: 10.1016/j.lwt.2021.111264
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of cattle bone collagen peptides-calcium chelate and its structural characterization and stability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
52
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 57 publications
(59 citation statements)
references
References 28 publications
5
52
2
Order By: Relevance
“…The amide I band of CPPs was detected around wave number 1,654.84 cm −1 , while the amide I band of CPP-Ca appeared at 1,655.86 cm −1 , suggesting the formation of peptide–calcium chelate was associated with C = O, and the complex have an α-helix structure. The vibration spectral region at 1,430–1,370 cm −1 is mainly caused by the stretching vibration of -COO- ( 39 ). After the interaction with calcium ions, the FTIR spectra shifted from 1,399.64 cm −1 to 1,413.93 cm −1 , which may be due to the interaction between the positive divalent calcium ions and -COO- to form -COO- Ca.…”
Section: Resultsmentioning
confidence: 99%
“…The amide I band of CPPs was detected around wave number 1,654.84 cm −1 , while the amide I band of CPP-Ca appeared at 1,655.86 cm −1 , suggesting the formation of peptide–calcium chelate was associated with C = O, and the complex have an α-helix structure. The vibration spectral region at 1,430–1,370 cm −1 is mainly caused by the stretching vibration of -COO- ( 39 ). After the interaction with calcium ions, the FTIR spectra shifted from 1,399.64 cm −1 to 1,413.93 cm −1 , which may be due to the interaction between the positive divalent calcium ions and -COO- to form -COO- Ca.…”
Section: Resultsmentioning
confidence: 99%
“…The molecular weight of the CP sample was analyzed using an HPLC apparatus (Agilent 1260, Agilent Technologies, Walnut Creek, CA, USA) equipped with DAWN HELEOS-II (Wyatt Technology Corporation, America) and Optilabr EX (Wyatt Technology Corporation, USA) detectors coupled with a TSK gel G4000PWxl column (7.8 × 300 mm, TOSOH, Tokyo, Japan), following the previous study ( 25 ). The mobile phase included 0.1% trifluoroacetic acid, 45% acetonitrile, and 54.9% ultrapure water (ultrapure water machine, Milli-Q Synthesis, Millipore Corporation, USA).…”
Section: Methodsmentioning
confidence: 99%
“…The peptide calcium was separated from the supernatant by absolute ethanol [ 32 ]. The supernatant with the same volume (V Ca ) was added to a centrifuge tube, mixed with absolute ethanol (1:5, v / v ), and then blended thoroughly with a vortex oscillator (MS3, IKA, Staufen, Germany) at 600 rpm for 5 min.…”
Section: Methodsmentioning
confidence: 99%