2017
DOI: 10.1016/j.radphyschem.2017.06.002
|View full text |Cite
|
Sign up to set email alerts
|

PRESAGE® as a solid 3-D radiation dosimeter: A review article

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 44 publications
(21 citation statements)
references
References 65 publications
0
21
0
Order By: Relevance
“…Various studies have analyzed the MRI response of polymer gels for possible application in radiotherapy dose mapping ([ 58 , 63 ] and references therein). In particular, polymer gels have been investigated for dosimetry in conformal therapy, IMRT, IMAT, IGRT, VMAT and tomotherapy [ 55 , 70 , 83 , 88 , 102 , 105 , 106 , 107 , 108 , 109 , 110 , 111 , 112 , 113 , 114 , 115 , 116 , 117 , 118 , 119 , 120 , 121 , 122 , 123 , 124 , 125 , 126 , 127 , 128 , 129 , 130 , 131 , 132 , 133 , 134 , 135 ], small photon fields [ 136 , 137 , 138 ], stereotactic radiosurgery [ 55 , 139 , 140 , 141 , 142 ], 60-cobalt source [ 143 , 144 ], brachytherapy [ 55 , 85 , 92 , 145 , ...…”
Section: Polyacrylamide Gelsmentioning
confidence: 99%
“…Various studies have analyzed the MRI response of polymer gels for possible application in radiotherapy dose mapping ([ 58 , 63 ] and references therein). In particular, polymer gels have been investigated for dosimetry in conformal therapy, IMRT, IMAT, IGRT, VMAT and tomotherapy [ 55 , 70 , 83 , 88 , 102 , 105 , 106 , 107 , 108 , 109 , 110 , 111 , 112 , 113 , 114 , 115 , 116 , 117 , 118 , 119 , 120 , 121 , 122 , 123 , 124 , 125 , 126 , 127 , 128 , 129 , 130 , 131 , 132 , 133 , 134 , 135 ], small photon fields [ 136 , 137 , 138 ], stereotactic radiosurgery [ 55 , 139 , 140 , 141 , 142 ], 60-cobalt source [ 143 , 144 ], brachytherapy [ 55 , 85 , 92 , 145 , ...…”
Section: Polyacrylamide Gelsmentioning
confidence: 99%
“…The high conformity of the prescribed dose with the planning target volume (PTV) can effectively kill cancerous cells while preserving the surrounding healthy tissue. [ 5 6 7 ]…”
Section: Challenges In Small-field Dosimetrymentioning
confidence: 99%
“…[ 81 ] These detectors are divided into three categories: Fricke, polymer, and radiochromic gels. [ 6 ] Fricke gels are highly reproducible and easy to prepare than other gel dosimeters, but diffusion in the gel is a disadvantage. [ 82 83 ] Polymer gels are high-sensitivity dosimeters without any diffusion issues; however, fabrication of these detectors is difficult due to their sensitivity to the presence of oxygen.…”
Section: Various Dosimeters Used In Small-field Dosimetrymentioning
confidence: 99%
See 1 more Smart Citation
“…Among various other dosimeters such as polymer and Fricke gels, required for 3D dosimetry, PRESAGE® (Heuris Pharma LLC, Skillman, NJ, USA) due to its dosimteric and physical properties is chosen in 3D dosimetry to give volumetric dose information. 1 PRESAGE is a radiochromic 3D dosimeter that was first fabricated in 2006. 2 It is basically a plastic material which is composed of leuco dye and an optically clear, solid polyurethane matrix with free radical initiators.…”
Section: Introductionmentioning
confidence: 99%