Preterm EEG: A Multimodal Neurophysiological Protocol

Abstract: Since its introduction in early 1950s, electroencephalography (EEG) has been widely used in the neonatal intensive care units (NICU) for assessment and monitoring of brain function in preterm and term babies. Most common indications are the diagnosis of epileptic seizures, assessment of brain maturity, and recovery from hypoxic-ischemic events. EEG recording techniques and the understanding of neonatal EEG signals have dramatically improved, but these advances have been slow to penetrate through the clinical t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
25
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(26 citation statements)
references
References 15 publications
1
25
0
Order By: Relevance
“…The routine EEG recording is performed with a NicOne (Cardinal Healthcare/Natus, USA) system and EEG caps (sintered Ag/AgCl electrodes; Waveguard, ANT-Neuro, Germany), which include 21 electrodes positioned according to the international 10-20 standard. For further details of the recording multichannel newborn EEG, please see (Vanhatalo et al, 2008;Stjerna et al, 2012) and http://www.nemo-europe.com/en/educationaltools.php/. The signals were collected at 2000 Hz, and we used Cz as a recording reference.…”
Section: Eeg-sep Measurement (Fig 1)mentioning
confidence: 99%
“…The routine EEG recording is performed with a NicOne (Cardinal Healthcare/Natus, USA) system and EEG caps (sintered Ag/AgCl electrodes; Waveguard, ANT-Neuro, Germany), which include 21 electrodes positioned according to the international 10-20 standard. For further details of the recording multichannel newborn EEG, please see (Vanhatalo et al, 2008;Stjerna et al, 2012) and http://www.nemo-europe.com/en/educationaltools.php/. The signals were collected at 2000 Hz, and we used Cz as a recording reference.…”
Section: Eeg-sep Measurement (Fig 1)mentioning
confidence: 99%
“…Sixty-four channel hdEEG caps were used (Waveguard, ANT B.V., Enschede, The Netherlands, www.ant-neuro.com; see also Stjerna et al, 2012). A video clip showing an EEG recording of this kind is shown in the link www.nemo-europe.com/en/educational-tools.php.…”
Section: Hdeeg Recordingmentioning
confidence: 99%
“…Functional assessment of neonatal brain activity is currently severely hampered by the poor spatial resolution provided by conventional neonatal EEG recording (Andre et al, 2010), which hardly suffices to distinguish brain lobes from each other. In order to meet the need for better spatial parcellation, several methods have been recently devised to enable recording of high density EEG (hdEEG) from the neonatal head in the laboratory environment (Fifer et al, 2006;Roche-Labarbe et al, 2008;Vanhatalo et al, 2008), and even in the neonatal intensive care unit (Stjerna et al, 2012;Vanhatalo et al, 2008).…”
Section: Introductionmentioning
confidence: 99%
“…Stjerna et al. used an EEG cap for preterm EEG monitoring and reported an effective technique of EEG application in preterm infants . An electrode cap array is undoubtedly an attractive option for infants, but a number of sizes are required for all gestational ages, and ideally, these hats need to be sterile and disposable.…”
Section: Discussionmentioning
confidence: 99%