Prismatic imaging polarimeter calibration for the infrared spectral region

Abstract: The calibration of a complete Stokes birefringent prismatic imaging polarimeter (BPIP) in the MWIR is demonstrated. The BPIP technique, originally developed by K. Oka, is implemented with a set of four Yttrium Vanadate (YVO(4)) crystal prisms. A mathematical model for the polarimeter is presented in which diattenuation due to Fresnel effects and dichroism in the crystal are included. An improved polarimetric calibration technique is introduced to remove the diattenuation effects, along with the relative radiom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 28 publications
(15 citation statements)
references
References 10 publications
0
15
0
Order By: Relevance
“…Such a phase extraction can be achieved within a single snapshot using Fourier transform techniques. [13][14][15][16][17][18] Expressing Eqs. (1) and (2) in terms of the general spatial coordinates (x, y) yields I R ¼ aðx; yÞ þ bðx; yÞ cosð2πx∕p 0 Þ…”
Section: Background: Fringe Projectionmentioning
confidence: 99%
“…Such a phase extraction can be achieved within a single snapshot using Fourier transform techniques. [13][14][15][16][17][18] Expressing Eqs. (1) and (2) in terms of the general spatial coordinates (x, y) yields I R ¼ aðx; yÞ þ bðx; yÞ cosð2πx∕p 0 Þ…”
Section: Background: Fringe Projectionmentioning
confidence: 99%
“…The CLI polarimeter is calibrated by applying the reference beam calibration technique [4,8]. First, a forward 2D Fourier transformation is performed on the intensity pattern of Eq.…”
Section: Polarimeter Calibrationmentioning
confidence: 99%
“…White-light interference fringes generated in the central 100 × 100 pixels on the focal plane array for generating polarizer orientations of (a) θ ¼ 0°, (b) θ ¼ 50°, and (c) θ ¼ 90°. spatial frequency content of the scene, thereby reducing aliasing artifacts in the reconstructed Stokes parameters [8,22]. A raw image of a moving vehicle, captured with the CLI polarimeter pictured in Fig.…”
Section: Outdoor Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…The amount of emission is based on each element's temperature. In Michael Kudenov's paper 12 , "Prismatic imaging polarimeter calibration for the infrared spectral region," he treats the calibration procedure for the system given in the following figure, This type of polarimeter is very similar to our system, because it too uses a spatially modulated image to back out the Stokes parameters. The basic system concept as far as the imaging polarimetry is the same, so calibration procedures for each will parallel each other.…”