2019
DOI: 10.1016/j.jddst.2019.01.012
|View full text |Cite
|
Sign up to set email alerts
|

Process optimization of ecological probe sonication technique for production of rifampicin loaded niosomes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 58 publications
(27 citation statements)
references
References 36 publications
0
27
0
Order By: Relevance
“…Nonetheless, the C=C stretching (at 1674 cm −1 ) zenith of the cholesterol faded, validating the cholesterol enclosure in the lipid bilayer [45]. Further, the prominent peaks of the drug molecule (E. angustifolia) were also absent in the niosomes' structures, which were observed by others as well [8,38].…”
Section: Fourier Transform Infrared (Ftir) Analysismentioning
confidence: 66%
See 1 more Smart Citation
“…Nonetheless, the C=C stretching (at 1674 cm −1 ) zenith of the cholesterol faded, validating the cholesterol enclosure in the lipid bilayer [45]. Further, the prominent peaks of the drug molecule (E. angustifolia) were also absent in the niosomes' structures, which were observed by others as well [8,38].…”
Section: Fourier Transform Infrared (Ftir) Analysismentioning
confidence: 66%
“…Many researchers have explored these colloidal emulsions in novel drug delivery systems for the therapeutic applications due to their excellent specification, such as insolubility, biocompatibility, and capability to carry both hydrophilic and hydrophobic drugs [5,6]. The content of surfactants and lipids can be altered to optimize the formulation size and the drug encapsulation efficiency to achieve high desired activity for each drug [7,8]. Various drugs have been formulated in the form of niosomes.…”
Section: Introductionmentioning
confidence: 99%
“…However, the N1S3 biolubricant displays weaker intensity of the peak of the O-H group than the N1S2 sample. This is probably a result of an excessive amount of surfactant which is more hydrophobic than NDCt [37].…”
Section: Resultsmentioning
confidence: 99%
“…Twenty scans were recorded for each spectrum. Smoothing was done where necessary to reduce the noise without loss of any peak [17].…”
Section: Fourier-transform Infrared Spectroscopy (Ftir)mentioning
confidence: 99%
“…Five milligrams of the scaffolds was taken into aluminum pans and was then hermetically sealed. A controlled heating and cooling rate was maintained at 10°C/min in nitrogen atmosphere [17]. The tensile or mechanical strength of the nanofibrous scaffolds were measured using a universal testing machine.…”
Section: Differential Scanning Calorimetrymentioning
confidence: 99%