Projection-based respiratory-resolved left ventricular volume measurements in patients using free-breathing double golden-angle 3D radial acquisition

Abstract: Objective To refine a new technique to measure respiratory-resolved left ventricular end-diastolic volume (LVEDV) in mid-inspiration and mid-expiration using a respiratory self-gating technique and demonstrate clinical feasibility in patients. Materials and methods Ten consecutive patients were imaged at 1.5 T during 10 min of free breathing using a 3D golden-angle radial trajectory. Two respiratory self-gating signals were extracted and compared: from the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 24 publications
0
2
0
Order By: Relevance
“…Two golden means from the Fibonacci series were used to calculate the azimuthal and polar angle of each radial spoke. To balance both a uniform k‐space coverage and eddy current artifacts, the fifth pair of golden means from the Fibonacci series was chosen (ie, ϕ11.26°$$ {\phi}_1\approx 1.26{}^{\circ} $$ and ϕ20.58°$$ {\phi}_2\approx 0.58{}^{\circ} $$) 20,21 . Both the azimuthal and polar angle completed a full rotation (ie, they were both defined between 0° and 360°), to minimize step size between successive spokes and thereby decrease eddy current artifacts 22 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Two golden means from the Fibonacci series were used to calculate the azimuthal and polar angle of each radial spoke. To balance both a uniform k‐space coverage and eddy current artifacts, the fifth pair of golden means from the Fibonacci series was chosen (ie, ϕ11.26°$$ {\phi}_1\approx 1.26{}^{\circ} $$ and ϕ20.58°$$ {\phi}_2\approx 0.58{}^{\circ} $$) 20,21 . Both the azimuthal and polar angle completed a full rotation (ie, they were both defined between 0° and 360°), to minimize step size between successive spokes and thereby decrease eddy current artifacts 22 .…”
Section: Methodsmentioning
confidence: 99%
“…To balance both a uniform k‐space coverage and eddy current artifacts, the fifth pair of golden means from the Fibonacci series was chosen (ie, and ). 20 , 21 Both the azimuthal and polar angle completed a full rotation (ie, they were both defined between 0° and 360°), to minimize step size between successive spokes and thereby decrease eddy current artifacts. 22 A slab‐selective excitation pulse in the maternal feet–head direction was implemented to reduce signal from spins outside the FOV.…”
Section: Methodsmentioning
confidence: 99%