2020
DOI: 10.1039/d0ob01389g
|View full text |Cite
|
Sign up to set email alerts
|

Prompt detection of endogenous hypochlorite (ClO) in murine macrophages and zebrafish embryos facilitated by a distinctive chemodosimetric mode

Abstract: An innovative Fluorescein appended naphthalene diimide based probe (FANDI) has been prepared and characterized to recognize hypochlorite or ClO- ion selectively in the presence of other reactive oxygen species (ROS)...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 46 publications
0
4
0
Order By: Relevance
“…The reaction mixture was refluxed for 4 h and then cooled to room temperature, poured into distilled water, and extracted with ethyl acetate (6 × 25 mL). The combined extract was washed with brine, dried with anhydrous sodium sulphate, filtered, and then concentrated under a reduced pressure to yield (71%) FH [52,53]. 1 H NMR (400 MHz, DMSO-d 6 ), δ (ppm): 6.47-6.39 (m, 4H), 6.60 (d, J= 3.0 Hz, 2H), 7.00-6.98 (m, 1H), 7.49 (t, J= 4.0 Hz, 2H), 7.79-7.77 (m, 1H), 9.84 (s, 2H).…”
Section: Practical Application In Water Samplesmentioning
confidence: 99%
“…The reaction mixture was refluxed for 4 h and then cooled to room temperature, poured into distilled water, and extracted with ethyl acetate (6 × 25 mL). The combined extract was washed with brine, dried with anhydrous sodium sulphate, filtered, and then concentrated under a reduced pressure to yield (71%) FH [52,53]. 1 H NMR (400 MHz, DMSO-d 6 ), δ (ppm): 6.47-6.39 (m, 4H), 6.60 (d, J= 3.0 Hz, 2H), 7.00-6.98 (m, 1H), 7.49 (t, J= 4.0 Hz, 2H), 7.79-7.77 (m, 1H), 9.84 (s, 2H).…”
Section: Practical Application In Water Samplesmentioning
confidence: 99%
“…Compared to the several analytical methods, [18][19][20][21][22] luminescent detection possesses promising features because of excellent selectivity, sensitivity, simple operation, and in vitro and in vivo HOCl imaging. [13,16,17,[23][24][25][26] Consequently, many luminescent probes have been developed for specific detection and imaging of HOCl. [16][17][18][19][20][21][22][23][24][25][26][27][28] To date, most of the fluorescent HOCl probes were designed based on the strong oxidation property of HOCl, such as oxidation of chalcogenides, p-methoxyphenol, BÀ H bond, pyrrole ring, and deoximation reactions.…”
Section: Introductionmentioning
confidence: 99%
“…[13,16,17,[23][24][25][26] Consequently, many luminescent probes have been developed for specific detection and imaging of HOCl. [16][17][18][19][20][21][22][23][24][25][26][27][28] To date, most of the fluorescent HOCl probes were designed based on the strong oxidation property of HOCl, such as oxidation of chalcogenides, p-methoxyphenol, BÀ H bond, pyrrole ring, and deoximation reactions. [29][30][31][32][33][34][35][36][37][38][39] Few probes have also been established for HOCl via epoxidation of acyclic C=C bond, [40,41] leading to the formation of the corresponding aldehyde.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation