Proposal to Modify the Polarimeter Chicane in the ILC 14 mrad Extraction Line

Abstract: A proposal is presented in this paper to modify the extraction line polarimeter chicane to allow the Compton backscattered electrons to be deflected further from the beam line, and to provide optics for the downstream GAMCAL detector. IntroductionThe current version of the extraction line polarimeter chicane as shown in figure 1 has four magnets located between z = 120 to 175 m [1]. We propose to run the last two polarimeter magnets BVEX3P and BVEX4P at 1½ the B-field of the first two magnets BVEX1P and BVEX2P… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 3 publications
0
14
0
Order By: Relevance
“…In the high background environment of the disrupted beam, the required high laser power allows measurement of only a few bunches out of each train. The chicane of the downstream polarimeter consists of six vertical bends to maximise the analysing power and to deflect the Compton-scattered electrons out of the synchrotron-radiation fan [187].…”
Section: Polarisation Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the high background environment of the disrupted beam, the required high laser power allows measurement of only a few bunches out of each train. The chicane of the downstream polarimeter consists of six vertical bends to maximise the analysing power and to deflect the Compton-scattered electrons out of the synchrotron-radiation fan [187].…”
Section: Polarisation Measurementsmentioning
confidence: 99%
“…The klystrons and modulators are installed on the surface in 22 groups or 'clusters' (11 per linac). Each cluster contains 18 or 19 klystrons, the combined RF power of which (180)(181)(182)(183)(184)(185)(186)(187)(188)(189)(190) is transported via a large 0.48 m-diameter overmoded cylindrical waveguide, first down a vertical shaft into the accelerator tunnel, and then along approximately 1 km of linac, where it drives ∼600 cavities ( Fig. 3.44).…”
Section: Introductionmentioning
confidence: 99%
“…2), a four bend vertical chicane for polarization measurement, and two vertical bends for gamma calorimeter luminosity diagnostics (Fig. 3) [8]. The polarimeter bends create 2 cm vertical dispersion at the Compton IP located at center of the polarimeter chicane.…”
Section: Extraction Line Opticsmentioning
confidence: 99%
“…[9] The downstream polarimeter chicane successfully accommodates a detector for the downstream energy spectrometer and provides magnetic elements for the GAMCAL system. [9] Figure 7: Schematic of the ILC extraction line diagnostics for the energy spectrometer and the Compton polarimeter.…”
Section: Downstream Polarimetermentioning
confidence: 99%