2011
DOI: 10.1016/j.radmeas.2011.07.035
|View full text |Cite
|
Sign up to set email alerts
|

Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 10 publications
0
8
0
Order By: Relevance
“…Contrary to the whole body dosimetry, eye lens dosimetry is not currently well established and numerous studies were carried out to investigate various aspects of eye dosimetry, such as the development of new dedicated eye dosemeters and calibration procedures [10,12,[26][27][28][29][30]. Furthermore, clinical studies have been conducted to discuss the methodology of the assessment of the eye lens dose levels, to investigate the monitoring arrangements using different types of dosemeters, to study correlations of eye lens dose with patient dose indices and to perform retrospective eye lens dose assessment [17,18,20,22,26].…”
Section: Approaches In Eye Lens Dose Assessment In Clinical Practicementioning
confidence: 99%
See 1 more Smart Citation
“…Contrary to the whole body dosimetry, eye lens dosimetry is not currently well established and numerous studies were carried out to investigate various aspects of eye dosimetry, such as the development of new dedicated eye dosemeters and calibration procedures [10,12,[26][27][28][29][30]. Furthermore, clinical studies have been conducted to discuss the methodology of the assessment of the eye lens dose levels, to investigate the monitoring arrangements using different types of dosemeters, to study correlations of eye lens dose with patient dose indices and to perform retrospective eye lens dose assessment [17,18,20,22,26].…”
Section: Approaches In Eye Lens Dose Assessment In Clinical Practicementioning
confidence: 99%
“…Generally they employ a thermoluminescent chip as passive dosemeter and some material covering it to mimic the necessary thickness to assure the coherence with the respective quantity definition [30,[32][33][34]. All these new devices should conform to suitable calibration procedures and type tests [29]. When a specific dosemeter is not available, Hp(3) can be estimated through dosemeters calibrated in terms of Hp (10) and Hp(0.07) through proper correction factors, [6,28,35].…”
Section: Eye Lens Dose Assessmentmentioning
confidence: 99%
“…The adoption of a corresponding PMMA waterfilled cylindrical phantom will be a consequence of the present proposal with its implications for the type testing and calibration criteria for eye-lens dosemeters (15) .…”
Section: Implications For the Dosemeter Type Test And Calibrationmentioning
confidence: 99%
“…In practice, the IEC 62387 standard is more exhaustive and hence should be preferred (Bordy et al, 2011).…”
Section: Conditions Of Calibration and Type Testing Of A Dosimeter Tomentioning
confidence: 99%