2022
DOI: 10.1007/s11695-022-06240-4
|View full text |Cite
|
Sign up to set email alerts
|

Prospective Randomized Comparison of Linear Endostaplers During Laparoscopic Sleeve Gastrectomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 15 publications
1
3
0
Order By: Relevance
“…The AEON™ stapler utilizes a three-layer staple technology, like all staplers, but its staple lengths are uniform, and this is a unique difference of AEON™ compared with the other commonly used staplers, which have a graduated staple height, as well as its multi-firing gear to accommodate the thicker tissues (see illustration ). In addition, the increased smoother articulation was subjectively observed, with no bleeding seen along the staple line in any case, similar to a randomized controlled trial in obesity surgery, with the conclusion that the AEON™ stapler causes less bleeding as a result of the staple technology used, but this cannot be ratified without a controlled study ( 12 ).…”
Section: Methodssupporting
confidence: 61%
See 1 more Smart Citation
“…The AEON™ stapler utilizes a three-layer staple technology, like all staplers, but its staple lengths are uniform, and this is a unique difference of AEON™ compared with the other commonly used staplers, which have a graduated staple height, as well as its multi-firing gear to accommodate the thicker tissues (see illustration ). In addition, the increased smoother articulation was subjectively observed, with no bleeding seen along the staple line in any case, similar to a randomized controlled trial in obesity surgery, with the conclusion that the AEON™ stapler causes less bleeding as a result of the staple technology used, but this cannot be ratified without a controlled study ( 12 ).…”
Section: Methodssupporting
confidence: 61%
“…Importantly, the multivarious analysis found that BMI > 30 kg/m 2 , male gender, and an additional procedure undertaken were significant predictors of a pancreatic fistula. The AEON™ stapler utilizes technology not apparent in other staplers with a uniform staple line height (see illustration) with the orange staple cartridge and gear adjustment for use in thicker tissue ( 12 ). One study reported a higher fistula rate in patients with a thicker pancreas (>12mm) ( 22 ), with other studies recommending a gradual graded approach to pancreatic transection, lasting 2 to 3 min as this may reduce the POPF rate ( 23 , 24 ).…”
Section: Discussionmentioning
confidence: 99%
“…Presuming that each selected reload is sized to align staple height with target tissue thickness, the staple line geometry of staggered and consistently sized staples may provide a better seal at the transection as compared with graduated staple heights where certain staples may be undersized while others oversized given the target tissue thickness. This difference in design may have contributed to clinical performance 23 …”
Section: Discussionmentioning
confidence: 99%
“…This difference in design may have contributed to clinical performance. 23 Historical 30-day overall complication rates have tended to be higher in patients undergoing laparoscopic RYGB (range: 1.5%-17.2%) 12,13,16,18,24,25 than in patients undergoing laparoscopic SG (range: 2%-8.4%), [12][13][14]25 due to the increased complexity of the operation. LSSD-A and LSSD-B were found to have comparable overall 30-day complication rates, with a trend (P < 0.1) towards fewer overall 30-day complications when treating with LSSD-A.…”
Section: Discussionmentioning
confidence: 99%