Prototype design for wearable veins localization system using near infrared imaging technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
27
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(28 citation statements)
references
References 5 publications
0
27
0
Order By: Relevance
“…In the electromagnetic spectrum’s range of 740 nm to 940 nm, the light can penetrate to about 5 mm deep of the skin tissue reaching the deoxygenated hemoglobin. The vein with the deoxygenated hemoglobin forms a dark contrast to the skin tissue due to the higher light absorption coefficient and lower backscatter light coefficient [48].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the electromagnetic spectrum’s range of 740 nm to 940 nm, the light can penetrate to about 5 mm deep of the skin tissue reaching the deoxygenated hemoglobin. The vein with the deoxygenated hemoglobin forms a dark contrast to the skin tissue due to the higher light absorption coefficient and lower backscatter light coefficient [48].…”
Section: Discussionmentioning
confidence: 99%
“…It is worth mentioning that regarding the device with 15–20 cm distance above the site: The allowable distance was set to ensure the needed space in performing a vein puncture in Kimori et al, 2015 [46] and the prototype by Meng, G. et al, 2015 [48] with a head wearable model. While, there was direct skin contact noted in some of the developed prototypes, the vein finder was introduced with the same purpose as a tourniquet, which is used to help locate the vein.…”
Section: Discussionmentioning
confidence: 99%
“…Its misrecognition rate was only 0.0001%, far below the 0.001% of the fingerprint and 1.3% of the face. Although fingerprint recognition technology and face recognition are developing rapidly, there are some flaws [1][2][3][4][5][6][7][8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Far-infrared (FIR) captures the tissue having a higher temperature than the adjacent 130 tissue in the surface and Near-infrared (NIR) captures the blood venous engrosses maximum of the infrared radiation than the adjacent tissue. Moreover, the NIR and FIR both cameras captured the light beyond the view of humans and the range of NIR illumination is around 740 nanometers to 940 nanometers and is capable to infiltrate 5mm subterranean into the skin tissue [7], [8].…”
Section: Introductionmentioning
confidence: 99%
“…Vein Viewer and CMOS camera and XBee pair with IR illuminator is a line of product which gives the practitioner a real-time image projected in on the patient arm and it uses the principle that infrared light is absorbed by the blood more than the surrounding tissue [3], [7]. However one of the most difficult issues in vein shape distinguishing proof by utilizing sensor combination between the devices [9].…”