PROXIMA 2A – A New Fully Tunable Micro-focus Beamline for Macromolecular Crystallography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
27
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 30 publications
(27 citation statements)
references
References 13 publications
0
27
0
Order By: Relevance
“…Diffraction data were collected either (i) on beamline PXII (Fuchs et al, 2014) equipped with a PILATUS 6M detector or beamline PXIII (Bingel-Erlenmeyer et al, 2011) equipped with a MAR CCD or a PILATUS 2M-F detector at the Swiss Light Source (SLS), Villigen, Switzerland, (ii) on the PROXIMA-2A (PX2A) beamline (Duran et al, 2013) equipped with an EIGER X 9M detector at SOLEIL, Saint-Aubin, France or (iii) on beamline ID30B (McCarthy et al, 2018) equipped with a PILATUS3 6M detector at the ESRF, Grenoble, France. All serial data collections were performed at room temperature (T = 293-298 K) on crystals inside ChipX3, owing to the reduced scattering background of the chip (Pinker et al, 2013).…”
Section: X-ray Data Collection and Analysismentioning
confidence: 99%
“…Diffraction data were collected either (i) on beamline PXII (Fuchs et al, 2014) equipped with a PILATUS 6M detector or beamline PXIII (Bingel-Erlenmeyer et al, 2011) equipped with a MAR CCD or a PILATUS 2M-F detector at the Swiss Light Source (SLS), Villigen, Switzerland, (ii) on the PROXIMA-2A (PX2A) beamline (Duran et al, 2013) equipped with an EIGER X 9M detector at SOLEIL, Saint-Aubin, France or (iii) on beamline ID30B (McCarthy et al, 2018) equipped with a PILATUS3 6M detector at the ESRF, Grenoble, France. All serial data collections were performed at room temperature (T = 293-298 K) on crystals inside ChipX3, owing to the reduced scattering background of the chip (Pinker et al, 2013).…”
Section: X-ray Data Collection and Analysismentioning
confidence: 99%
“…Unfortunately, the initial data set collected on ID23-1 for the 2c complex could not be refined with good statistics, probably because of superposition of diffraction from microcrystals of the poorly solubilized ligand. It was recollected on beamline Proxima-2A 35 at the Soleil storage ring in St. Aubin, France. To recollect the data, crystals that had dried out after 18-month storage were re-hydrated by the addition of 300 mL of water to the sitting drop reservoir.…”
Section: Crystal Preparation and Structure Determinationmentioning
confidence: 99%
“…In order to achieve both requirements, we recently developed a double surface bimorph mirror for the back-end horizontal beamline optics in combination with the secondary source beamline design. The same type of the double surface bimorph mirror was developed at the PROXIMA 2A beamline at SOLEIL for two different focusing configurations at one focal distance [2]. On the other hand, our mirror supplies three characteristic beams for the focal positions which are away from each other.…”
Section: Introductionmentioning
confidence: 99%