Proximal RUMM block in dogs: preliminary results of cadaveric and clinical studies

Abstract: Objective To evaluate intra and postoperative efficacy of an ultrasound (US)-guided radial (R), ulnar (U), median (M) and musculocutaneous (Mc) nerve blocks, performed together in the axillary space by a single in-plane approach.Study design Anatomical research and prospective clinical study.Animals Three dog cadavers and 15 client-owned dogs undergoing thoracic orthopaedic limb surgery. MethodsIn Phase-1, anatomical dissection and US study of the axillary space were performed to design an US-guided proximal R… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
1
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(20 citation statements)
references
References 33 publications
0
17
1
2
Order By: Relevance
“…Evidence for an axillary sheath surrounding the R, U, M and Mc nerves has recently been described in dogs. 8 Despite no visualisation of one in this study, its existence in the cat is plausible and may explain the variability in nerve stain characteristics between specimens, as well as the complete stain failures in specimens 5 and 7. In these specific specimens (5 and 7), injected solution between the triceps muscles indicate incorrect needle placement, possibly outside a fascial plane.…”
Section: Discussionmentioning
confidence: 78%
See 3 more Smart Citations
“…Evidence for an axillary sheath surrounding the R, U, M and Mc nerves has recently been described in dogs. 8 Despite no visualisation of one in this study, its existence in the cat is plausible and may explain the variability in nerve stain characteristics between specimens, as well as the complete stain failures in specimens 5 and 7. In these specific specimens (5 and 7), injected solution between the triceps muscles indicate incorrect needle placement, possibly outside a fascial plane.…”
Section: Discussionmentioning
confidence: 78%
“…The current study describes a 20 mm target stain length, as do most cadaveric studies. 8,15,16 The dose rate of 0.2 ml/kg body weight was extrapolated from Campoy et al 15 and aimed to minimise the risks of collateral nerve staining when using larger volumes as documented by Anson et al 3 As with most cadaveric studies, major limitations to this study include undetected neurovascular damage and translating how nerve staining (block) relates to nerve desensitisation clinically. Using this modified lateral approach, theoretical damage may be possible to the axillary artery, its continuation as the brachial artery and the cranial and caudal circumflex arteries.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…O restante da solução é aplicado lentamente para o bloqueio completo do plexo braquial opióides mu e kappa de rápida ação (<1-2 min), curta duração (20-30 min) e elevada potência, 100 vezes maior do que a da morfina (GRUBB et al, 2020). Em um estudo realizado (TAYARI et al, 2019), três dos 15 animais submetidos a cirurgias ortopédicas de membros torácicos, necessitaram de resgate analgésico, sendo assim aplicado fentanil…”
Section: Discussionunclassified