X-Ray Nanoimaging: Instruments and Methods IV 2019
DOI: 10.1117/12.2529096
|View full text |Cite
|
Sign up to set email alerts
|

Ptychographic Nano-Analytical Microscope (PtyNAMi) at PETRA III: signal-to-background optimization for imaging with high sensitivity

Abstract: The X-ray scanning microscope PtyNAMi at beamline P06 of PETRA III at DESY in Hamburg, Germany, is designed for high-spatial-resolution 3D imaging with high sensitivity. Besides optimizing the coherent flux density on the sample and the precision mechanics of the scanner, special care has been taken to reduce background signals on the detector. The optical path behind the sample is evacuated up until the sensor of a four-megapixel detector that is placed into the vacuum. In this way, parasitic scattering from … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
6

Relationship

5
1

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 43 publications
0
9
0
Order By: Relevance
“…Ptychography: An area detector (Eiger X 4M, Dectris, Baden-Daettwil, Switzerland) was placed m downstream of the sample, in the experimental nanoprobe hutch of beamline P06 [ 35 ], to measure the far-field diffraction patterns. The detector was set up in vacuum ( ) with a flight tube to minimize the air path between sample and detector [ 36 ].…”
Section: Materials and Methodsmentioning
confidence: 99%
“…Ptychography: An area detector (Eiger X 4M, Dectris, Baden-Daettwil, Switzerland) was placed m downstream of the sample, in the experimental nanoprobe hutch of beamline P06 [ 35 ], to measure the far-field diffraction patterns. The detector was set up in vacuum ( ) with a flight tube to minimize the air path between sample and detector [ 36 ].…”
Section: Materials and Methodsmentioning
confidence: 99%
“…Experiment: single polyimide foil. The experiment was performed at the hard X-ray nanoprobe station PtyNAMi of beamline P06 at the synchrotron radiation source PETRA III (Hamburg, Germany) 44,45 . The polyimide foil with the copper(I) oxide particles on both sides was glued to a thin silicon frame, covering a hole of 10 mm diameter.…”
Section: Methodsmentioning
confidence: 99%
“…Experiment: chemical reactor. The experiment was again performed at the hard X-ray nanoprobe station PtyNAMi of beamline P06 at the synchrotron radiation source PETRA III (Hamburg, Germany) 44,45 . The whole chemical reactor with all connections needed to potentially operated it, was placed inside the PtyNAMi setup 46,47 .…”
Section: Methodsmentioning
confidence: 99%
“…Imaging ( i . e ., spatial resolution) (see Figure a) based on X-ray transmission, fluorescence, (coherent) scattering, diffraction, or phase contrast techniques has been demonstrated using synchrotron radiation. ,,, Furthermore, recently developed nanoprobe beamlines , possess advanced X-ray optics which are capable of focusing synchrotron radiation below 50 nm, allowing the use of X-ray imaging techniques to study biological samples with subcellular resolution.…”
Section: X-ray-based Techniques As An Alternative To Study Nanopartic...mentioning
confidence: 99%