2019
DOI: 10.1007/s00216-018-1552-2
|View full text |Cite
|
Sign up to set email alerts
|

Pullulan reduces the non-specific amplification of loop-mediated isothermal amplification (LAMP)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(18 citation statements)
references
References 34 publications
1
17
0
Order By: Relevance
“…This device operates by detecting viral nucleic acids such as the reference standard (RT-PCR) and isothermal amplification tests. RT-LAMP amplification unfortunately has issues such as: non-specific amplification that can be a problem in later steps as a result of “carry-over contamination”, “product cross contamination” [ 28 , 29 , 30 ], or primer hybridization [ 31 ].…”
Section: Discussionmentioning
confidence: 99%
“…This device operates by detecting viral nucleic acids such as the reference standard (RT-PCR) and isothermal amplification tests. RT-LAMP amplification unfortunately has issues such as: non-specific amplification that can be a problem in later steps as a result of “carry-over contamination”, “product cross contamination” [ 28 , 29 , 30 ], or primer hybridization [ 31 ].…”
Section: Discussionmentioning
confidence: 99%
“…Hence, LAMP can be used as a reli able method for the diagnostics of Plasmodium species. However, in another study, LAMP based assay produced some false positives [15]. LAMP was successfully used for identification of Salmonella in food products in situ and detection of stxA2 (Shiga toxin 2 subunit A) in Escherichia coli O157:H7 cells [15a, 15b].…”
Section: Amplification Techniques That Increase Analytical Signal By mentioning
confidence: 99%
“…One of the limitations of colorimetric LAMP-based methods based on the phenol red color shift is that some degree of color change exists in samples containing no template (see ref [29]). This has been associated to the occurrence of nonspecific amplification induced by the interaction among the LAMP primers [24,34], which often serve as templates for off-target polymerizations. In general, nonspecific amplification is believed to be the main reason for false positives in LAMP colorimetric reactions.…”
Section: Lf-qlamp In Saliva Samples: Discrimination Between Positive and Negative Samplesmentioning
confidence: 99%
“…LAMP-based methods also use from four to six primer sets, and the design of LAMP primer sets is nontrivial as the primers may interact among themselves during amplification. This can promote nonspecific amplifications that may also result in false positives [23,24].…”
Section: Introductionmentioning
confidence: 99%