QT PRODACT: Inter-facility Variability in Electrocardiographic and Hemodynamic Parameters in Conscious Dogs and Monkeys

Abstract: Abstract. In safety pharmacology studies, the effect of a test compound on the electrocardiogram is routinely examined by using conscious dogs. However, the results may be widely variable. The monkey, on the other hand, has scarcely been used for such studies; and as yet, there have not been reported studies on monkeys conducted at several facilities with a standard protocol. In the present study, we examined inter-facility variabilities in electrocardiographic and hemodynamic parameters as described below. We… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
16
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
5
4
1

Relationship

3
7

Authors

Journals

citations
Cited by 38 publications
(18 citation statements)
references
References 49 publications
2
16
0
Order By: Relevance
“…Moreover, in the light cycle, the scattering of the QTcB intervals from the control baseline values in 4 animals in different testing facilities was within 10% (12). This observation supports the results that a more than 10% change in the QTcB interval compared with the control baseline is considered to be caused by a test compound.…”
Section: Circadian Rhythms For Mbp and Electrophysiological Parametersupporting
confidence: 86%
“…Moreover, in the light cycle, the scattering of the QTcB intervals from the control baseline values in 4 animals in different testing facilities was within 10% (12). This observation supports the results that a more than 10% change in the QTcB interval compared with the control baseline is considered to be caused by a test compound.…”
Section: Circadian Rhythms For Mbp and Electrophysiological Parametersupporting
confidence: 86%
“…After completion of the series of experiments, the vehicle and dl-sotalol hydrochloride (sotalol), a common positive compound, were administered to the same animals to investigate the interfacility variability. The results are reported by Sasaki et al (7) in this issue.…”
Section: Group Composition and Administrationsupporting
confidence: 69%
“…By publishing the data and providing recommendations on its use, it is hoped that this will be regarded as a reference guide for other researchers and scientific reviewers within regulatory agencies. Previous examples of publications on interlaboratory concordance in safety pharmacology-related studies include those on the functional observational battery (FOB; Moser, Becking, MacPhail, & Kulig, 1997) and on QTc effects detected using dog cardiovascular telemetry (Sasaki, Shimizu, Suganami, & Yamamoto, 2005).…”
Section: Discussionmentioning
confidence: 99%