2022
DOI: 10.1016/j.jchromb.2022.123472
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of cyclic AMP and cyclic GMP levels in Krebs-Henseleit solution by LC-MS/MS: Application in washed platelet aggregation samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2

Relationship

4
3

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…However, it is unlikely that 6-ND acts as a PDE3 inhibitor since, when incubated in the rat isolated right atrium, it abolishes the concentration-dependent increase in the atrial rate induced by milrinone or cilostazol [59]. In addition, incubation of 6-ND with human washed platelets was not accompanied by a change in nucleotide levels [60].…”
Section: Discussionmentioning
confidence: 97%
“…However, it is unlikely that 6-ND acts as a PDE3 inhibitor since, when incubated in the rat isolated right atrium, it abolishes the concentration-dependent increase in the atrial rate induced by milrinone or cilostazol [59]. In addition, incubation of 6-ND with human washed platelets was not accompanied by a change in nucleotide levels [60].…”
Section: Discussionmentioning
confidence: 97%
“…Since the relaxation of the vascular smooth muscle is attributed to soluble guanylate cyclase and cGMP generation ( 48 ), and the relaxation induced by 6-ND was unaltered by soluble guanylyl cyclase inhibition, the synthesis of 6-ND constitutes an additional pathway by which NO causes vasorelaxation. Indeed, 6-nitrodopamine failed to increase cGMP levels in human washed platelets ( 49 ). The relaxation caused by 6-ND was not affected by pretreatment of the vascular rings with the dopamine D 1 R antagonist SCH-23390 ( 50 ), supporting the hypothesis that 6-ND is acting as a selective D 2 -like antagonist.…”
Section: Actions Of 6-nitrodopamine In the Vascular Smooth Musclementioning
confidence: 99%
“…LC-MS/MS detection of cAMP and 5-HIAA LC-MS/MS was used to detect cAMP and 5-HIAA concentrations, as previously described [51,52]. Liquid chromatography was performed using a Prominence® HPLC system (Shimadzu, Tokyo, Japan), comprising a solvent delivery unit LC-20AD, an autosampler SIL-20AC, and a column oven CTO-20AC.…”
Section: Rna Extraction Library Construction and Bioinformatics Analy...mentioning
confidence: 99%