2015
DOI: 10.1016/j.ultras.2014.07.013
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of elasticity changes in the myometrium during labor using Supersonic Shear Imaging: A feasibility study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
19
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(20 citation statements)
references
References 30 publications
1
19
0
Order By: Relevance
“…US elastography is increasingly used for the diagnosis of stiffness in numerous circumscribed tissues [1,[4][5][6][7][8][9][10][11][12][13][14][15][16][17]. To date, there has been a lack of phantom studies which have systematically assessed the current US shear wave elastography techniques (pSWE with fixed ROI vs. 2D-SWE with variable ROI) in an effort to evaluate their suitability/test performance for this condition.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…US elastography is increasingly used for the diagnosis of stiffness in numerous circumscribed tissues [1,[4][5][6][7][8][9][10][11][12][13][14][15][16][17]. To date, there has been a lack of phantom studies which have systematically assessed the current US shear wave elastography techniques (pSWE with fixed ROI vs. 2D-SWE with variable ROI) in an effort to evaluate their suitability/test performance for this condition.…”
Section: Discussionmentioning
confidence: 99%
“…Elastic properties of circumscribed tissues and organs that are not accessible to physicians' hands (a), or which require measurements in a small, localized area (b) are of considerable clinical interest [1,[4][5][6][7][8][9][10][11][12][13][14][15][16][17]. Examples are: tendons/ligaments a/b , lymph nodes a/b , myometria a , prostates b , cervix uteri b , testicles b , anal sphincter muscles b , arterial plaques a/b , muscles a , intervertebral discs a/b , thyroid nodules a/b , and brain tumors a/b .…”
Section: Introductionmentioning
confidence: 99%
“…In a recent study, Gennisson at al. [26] assessed the elasticity changes in the myometrium during labor using the same technique. The sensitivity of the technique in cervical tissue was already reported in a previous study performed in animals [16].…”
Section: Discussionmentioning
confidence: 99%
“…It has been used in the examination of breast, thyroid and liver masses and for measuring cervix elasticity, placental insufficiency and in studying the myometrium during labor [27–29]. SWE uses acoustic radiation to generate a shear wave which is a cone-shaped force that is measured using high velocity ultrasound at around 5000 to 20,000 KHz [28].…”
Section: Discussionmentioning
confidence: 99%
“…The placenta has been examined as well to examine the elastic modulus of the placenta in comparison to other established measures of placental perfusion and is found to have potential for measurement of placental function [27]. Of note, a similar study on the myometrium using SWE to measure uterine contractions during labor used an elastogram window of 18 by 15 mm squared [29]. In another study, the resolution of ultrasound elastography has been reported to be as low as hundreds of microns, though it is not clear if this is possible in vivo [30].…”
Section: Discussionmentioning
confidence: 99%