2001
DOI: 10.1364/ao.40.004416
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative analysis of decay transients applied to a multimode pulsed cavity ringdown experiment

Abstract: The intensity and noise properties of decay transients obtained in a generic pulsed cavity ringdown experiment are analyzed experimentally and theoretically. A weighted nonlinear least-squares analysis of digitized decay transients is shown that avoids baseline offset effects that induce systematic deviations in the estimation of decay rates. As follows from simulations not only is it a method that provides correct estimates for the values of the fit parameters, but moreover it also yields a correct estimate o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
32
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 48 publications
(32 citation statements)
references
References 34 publications
0
32
0
Order By: Relevance
“…As previously discussed, excitation with narrow-band radiation from injection-seeded Nd:YAG lasers would result in mode-beating on the transients, 23 and therefore the 532 nm radiation at sufficiently large bandwidth was produced through the use of an optical parametric oscillator (OPO) pumped with the third harmonic of a Coherent Infinity single-mode Nd:YAG laser (Santa Clara, CA) at 355 nm; 2 this laser has the advantage that the repetition frequency can be varied between 10 and 100 Hz without modifications to the beam profile.…”
Section: Methodsmentioning
confidence: 89%
“…As previously discussed, excitation with narrow-band radiation from injection-seeded Nd:YAG lasers would result in mode-beating on the transients, 23 and therefore the 532 nm radiation at sufficiently large bandwidth was produced through the use of an optical parametric oscillator (OPO) pumped with the third harmonic of a Coherent Infinity single-mode Nd:YAG laser (Santa Clara, CA) at 355 nm; 2 this laser has the advantage that the repetition frequency can be varied between 10 and 100 Hz without modifications to the beam profile.…”
Section: Methodsmentioning
confidence: 89%
“…As was elaborated by Naus et al [4] a weighted non-linear least-squares fit to the data on the transient give the best determination of the decay life time, and in particular produces a reliable estimate of the uncertainty. As for the optical resonator it is important that it is aligned such that its mode structure does not result in wavelength-dependent effects.…”
Section: Principles Of Cavity Ring-down Spectroscopymentioning
confidence: 99%
“…The optical resonator then acts as a white-light filter and the configuration can be used for wavelength-scanning pulsed CRDS. The relation between mode-structure and transmission, and an experimental method to improve alignment towards single-exponential decay in a non-confocal resonator were discussed in reference [4].…”
Section: Principles Of Cavity Ring-down Spectroscopymentioning
confidence: 99%
“…If the transverse modes are suppressed, the equation takes the form of the equally spaced ( ν = c 2L spaced) transmission fringes of an etalon; this condition can be most easily met under confocal conditions (L = R c ). If transversal modes are excited, and if the resonator length is sufficiently far away from the confocal condition, the filling-in of transverse modes may become so dense that the resonator becomes a white-light attenuator/transmitter (53). This condition is particularly useful for cavity ring-down experiments, as the transmission of the resonator (and therefore the ring-down properties) becomes wavelength independent.…”
Section: Cavity Ring-down Spectroscopy: Principles and Techniquesmentioning