2008
DOI: 10.1002/rcm.3377
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative analysis of small molecules by desorption electrospray ionization mass spectrometry from polytetrafluoroethylene surfaces

Abstract: Desorption electrospray ionization mass spectrometry (DESI-MS) is an emerging technique for ambient analysis. However, its application to routine quantitation has not been explored extensively and this is undertaken here. We present studies that utilize a particularly suitable surface, porous polytetrafluoroethylene (porous PTFE), which shows less cross contamination between samples and improved sensitivity and signal stability compared to other surfaces. Quantitative experiments for 1 microL spotted solutions… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
109
0

Year Published

2009
2009
2014
2014

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 123 publications
(113 citation statements)
references
References 37 publications
4
109
0
Order By: Relevance
“…DESI analysis was performed on four types of samples in a 96-sample array in the course of a single experiment: two sample types were free of any chemical background, one was made in a 10% urine solution, and one in 250 ng/ L brain total lipid extract. Isotopically labeled standards were selected to minimize complicating effects that might arise from the use of chemically similar but distinct standards [18]. The total analysis time per sample (including analysis time and the time required to move between samples) was 1.5 s for background-free samples and 2.5 s for the samples in a biological milieu, allowing the entire 96 sample plate to be analyzed in just over 3 min.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…DESI analysis was performed on four types of samples in a 96-sample array in the course of a single experiment: two sample types were free of any chemical background, one was made in a 10% urine solution, and one in 250 ng/ L brain total lipid extract. Isotopically labeled standards were selected to minimize complicating effects that might arise from the use of chemically similar but distinct standards [18]. The total analysis time per sample (including analysis time and the time required to move between samples) was 1.5 s for background-free samples and 2.5 s for the samples in a biological milieu, allowing the entire 96 sample plate to be analyzed in just over 3 min.…”
Section: Resultsmentioning
confidence: 99%
“…To explore this application, we procured custom-made PTFE printed glass slides in a 96-sample format (Figure 1). This PTFE printed glass substrate has been shown to be an effective and versatile surface for DESI that gives strong, stable signal for a wide array of analytes [18,20]. This system offers several advantages.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations